ZN63A(VS1)-12/24 fixed-type indoor high voltage vacuum circuit breaker
Type Designation

| 1 | Vacuum Circuit Breaker |
| 2 | Indoor |
| 3 | Design Serial Number |
| 4 | Rated Voltage (kV) |
| 5 | Rated Current (A) |
| 6 | Rated Short-Circuit Breaking Current (kA) |
Technical Parameters
| No. | Item | Unit | Partmeter | ||||
| 1 | Rated Voltage | kV | 12 | 24 | |||
| 2 | Rated Insulation Level | 1min Power Frequency Withstand Voltage (r.m.s.) | 42 | 65 | |||
| 3 | Lightning Impulse Withstand Voltage (peak) | 75 | 125 | ||||
| 4 | Rated Frequency | Hz | 50/60 | ||||
| 5 | Rated Current | A | 630,1250 | 630,1250,1600, 2000,2500,3150 |
1250,1600,2000, 2500,3150,4000* |
||
| 6 | Rated Short-Circuit Breaking Current | kA | 20/25 | 31.5 | 40 | ||
| 7 | Rated Short-Time Withstand Current | 20/25 | 31.5 | 40 | |||
| 8 | Rated Short-Duration Power Frequency Withstand Voltage | S | 4 | ||||
| 9 | Rated Peak Withstand Current | kA | 50/63 | 80 | 100 | ||
| 10 | Rated Short-Circuit Making Current | 50/63 | 80 | 100 | |||
| 11 | Rated Capacitor Bank Breaking Current | A | 630 | ||||
| 12 | Rated Short-Circuit Breaking Current Breaking Times | time | 30(Class E2) | ||||
| 13 | Mechanical Life | ≥20000(Class M2) | |||||
| 14 | Contact Gap | mm | 9±1 | 13±1 | |||
| 15 | Contact Travel | 3.5±0.5 | 4±1 | ||||
| 16 | Average Closing Speed | m/s | 0.6±0.2 | 0.8±0.2 | |||
| 17 | Average Opening Speed | 1.1±0.2 | 1.3±0.2 | ||||
| 18 | Opening Time (at rated voltage) | ms | ≤40 | ≤50 | |||
| 19 | Closing Time (at rated voltage) | ≤60 | ≤75 | ||||
| 20 | Contact Closing Bounce Time | ≤2 | |||||
| 21 | Three-Phase Closing Non-Simultaneity | ≤2 | |||||
| 22 | Allowable Cumulative Wear Thickness of Moving and Fixed Contacts | mm | 3 | ||||
| 23 | Main Circuit Resistance | μΩ | ≤60(630A) | ≤50(1250A) | ≤35(1600~4000A) | ||
| 24 | Rated Operating Sequence | O-0.3s-CO-180s-CO;O-180s-CO-180s-CO(40kA) | |||||
| Note: Forced air cooling is required for 4000A and above. | |||||||
product Display
Outline and Installation Dimension
1.Drawing of Overall Dimensions for ZN63A(VS1)-12 Fixed Type (Phase Distance 150mm) Circuit Breaker

| Rated Current (A) | 630 | 1250 |
| Rated Short-Circuit Breaking Current (kA) | 20,25,31.5 | 25,31.5 |
| Phase Distance (mm) | 150±1.5 | |
| Mechanism Top Interlock L1 (mm) | 45 (Interlock extends left or right; length can be customized as required) | |
| Mechanism Main Shaft Interlock L2 (mm) | 45 (Interlock extends left or right; length can be customized as required) | |
2.Drawing of Overall Dimensions for ZN63A(VS1)-12 Fixed Type (Phase Distance 210mm) Circuit Breaker

| Rated Current (A) | 630 | 1250 | 1600 |
| Rated Short-Circuit Breaking Current (kA) | 20,25,31.5 | 25,31.5,40 | 31.5 |
| Phase Distance (mm) | 210±1.5 | ||
| Mechanism Top Interlock L1 (mm) | 45 (Interlock extends left or right; length can be customized as required) | ||
| Mechanism Main Shaft Interlock L2 (mm) | 45 (Interlock extends left or right; length can be customized as required) | ||
3.Drawing of Overall Dimensions for ZN63A(VS1)-12 Fixed Type (Phase Distance 275mm) Circuit Breaker

| Rated Current (A) | 1600,2000,2500,3150 |
| Rated Short-Circuit Breaking Current (kA) | 31.5,40 |
| Phase Distance (mm) | 275±1.5 |
| Mechanism Top Interlock L1 (mm) | 45 (Interlock extends left or right; length can be customized as required) |
| Mechanism Main Shaft Interlock L2 (mm) | 45 (Interlock extends left or right; length can be customized as required) |
4.Drawing of Overall Dimensions for ZN63A(VS1)-24 Fixed Type Circuit Breaker

| Rated Current (A) | 630 | 1250 | 1600 |
| Rated Short-Circuit Breaking Current (kA) | 20,25,31.5 | 25,31.5,40 | 31.5 |
| Phase Distance (mm) | 275±1.5 | ||
| Mechanism Top Interlock L1 (mm) | 45 (Interlock extends left or right; length can be customized as required) | ||
| Mechanism Main Shaft Interlock L2 (mm) | 45 (Interlock extends left or right; length can be customized as required) | ||
| Rated Current (A) | 1600,2000,2500,3150 | 4000 |
| Rated Short-Circuit Breaking Current (kA) | 31.5,40 | 40 |
| Phase Distance (mm) | 275±1.5 | |
| Mechanism Top Interlock L1 (mm) | 45 (Interlock extends left or right; length can be customized as required) | |
| Mechanism Main Shaft Interlock L2 (mm) | 45 (Interlock extends left or right; length can be customized as required) | |
Arc Extinguishing Principle
The ZN63A(VS1)-12/24 series circuit breaker utilizes a vacuum interrupter with a high degree of vacuum. During normal opening or short-circuit interruption, the moving contact is driven by the operating mechanism, causing it to separate from the fixed contact and generate an arc between them. Due to the special design of the moving and fixed contacts, an axial magnetic field is generated between them. This field controls the arc, causing it to burn uniformly and move across the contact surface while maintaining a low arc voltage. When the arc current naturally passes through zero, the remaining ions, electrons, and metal vapor, under the influence of the electromagnetic field, quickly recombine or condense on the contact surfaces and the shield. The dielectric strength across the interrupter gap is rapidly restored, thereby extinguishing the arc and achieving the purpose of interruption.