W1 ACB Intelligent Universal Circuit Breaker from China Suppliers and Factory for Reliable Power Protection
Type Designation

| No. | Description |
| 1 | Enterprise code |
| 2 | Universal circuit breaker |
| 3 | Design serial number |
| 4 | Rated current of circuit breaker frame level |
| 5 | Number of poles: 4-pole marked as 4, no marking for 3-pole |
Product Display
Product Structure Diagram

- ① Secondary Circuit Terminal
- ② Close Button
- ③ Trip Button
- ④ Manual Energy Storage Handle
- ⑤ Close/Trip Position Indicator
- ⑥ Energy Storage and Release Indicator
- ⑦ Front Panel
- ⑧ In/Out Device
- ⑨ Position Indicator
- ⑩ Hand Crank and Its Storage

- 1. Secondary Circuit Terminal (Fixed)
- 2. Drawer Chassis
- 3. Safety Barrier
- 4. Secondary Circuit Terminal (Movable)
- 5. Auxiliary Contact
- 6. Shunt Release
- 7. Under Voltage Release
- 8. Closing Electromagnet
- 9. Operating Mechanism
- 10. Motorized Smart Mechanism
- 11. Intelligent Controller
- 12. Front Panel
Technical Parameters
| Category | 2000A Frame Level | 3200A Frame Level | 4000A Frame Level | 6300A Frame Level | |
| Rated Current (A) | 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000 | 2000, 2500, 2900, 3200 | 3200, 3600, 4000 | 4000, 5000, 6300 | |
| Total Number of Operating Cycles | 10000 | 5000 | 5000 | 2000 | |
| Rated Short-Circuit Breaking Capacity Icu (kA) O-Co | 400V | 80 | 100 | 100 | 120 |
| 690V | 50 | 65 | 65 | 80 | |
| Rated Short-Circuit Making Capacity nxlcu (kA) / cosA | 400V | 176/0.2 | 220/0.2 | 220/0.2 | 264/0.2 |
| 690V | 105/0.25 | 143/0.2 | 143/0.2 | 187/0.2 | |
| Service Short-Circuit Breaking Capacity Ics (kA) O-C0-Co | 400V | 50 | 65 | 80 | 100 |
| 690V | 40 | 50 | 65 | 80 | |
| Rated Short-Time Withstand Current Icw (kA) 1s, 0.4s, 0-Co | 400V | 50 | 65 | 65/80(MCR) | 85/100(MCR) |
| 690V | 40 | 50 | 50/65(MCR) | 65/75(MCR) | |
| Operating Voltage & Power Requirements | |||||
| Power Required Rated Operating Voltage | AC (50Hz) | DC | |||
| Unit | AC220V | AC380V | DC110V | DC220V | |
| Shunt Release | 24VA | 36VA | 24VA | 24VA | |
| Undervoltage Release | 24VA | 36VA | - | - | |
| Closing Electromagnet | 24VA | 36VA | 24VA | 24VA | |
| Motorized Operating Mechanism | 2000A | 85VA | 85VA | 85VA | 85VA |
| 3200A, 4000A | 110VA | 110VA | 110VA | 110VA | |
| 6300A | 150VA | 150VA | 150VA | 150VA | |
| Intelligent Controller Power Supply Voltage | AC220V, AC380V, DC220V, DC110V | ||||
| Note: The reliable operating voltage range is 70%–110% for shunt release, and 80%–110% for closing electromagnet and operating mechanism. | |||||
Installation Dimensions and Overall Dimensions
| Installation dimensions and overall dimensions | In(A) | a(mm) | b(mm) | e(mm) |
| Fixed Circuit Breaker (2000, 2000/4) | 400–800 | 10 | 95 | 38 |
| 1000–1600 | 15 | 105 | 48 | |
| 2000 | 20 | 115 | 58 | |
| Fixed Circuit Breaker (3200, 3200/4) | 2000–2500 | 20 | 115 | 23 |
| 2900–3200 | 30 | 135 | 43 | |
| Drawer-Type Circuit Breaker (1000, 2000/3, 4) | 400–800 | 10 | 95 | 3 |
| 1000–1600 | 15 | 105 | 13 | |
| 2000 | 20 | 115 | 23 | |
| Drawer-Type Circuit Breaker (3200, 3200/4) | 2000–2500 | 20 | 115 | 58 |
| 2900–3200 | 30 | 135 | 78 | |
| Drawer-Type Circuit Breaker (4000) | Note: The horizontal center-to-center distance between the panel and circuit breaker shall be 57.5mm | |||
| Drawer-Type Circuit Breaker (4000/4) | Note: The horizontal center-to-center distance between the panel and circuit breaker shall be 206.5mm | |||
| Drawer-Type Circuit Breaker (6300A, 6300/4 In=4000A, 5000A) | Note: The horizontal center-to-center distance between the panel and circuit breaker shall be 189mm (3-pole), 246.5mm (4-pole) | |||
| Drawer-Type Circuit Breaker (6300 In=6300A) | Note: The horizontal center-to-center distance between the panel and circuit breaker shall be 246.5mm | |||
| Drawer-Type Circuit Breaker (6300A) | Note: The horizontal center-to-center distance between the panel and circuit breaker shall be 304mm | |||
◆ Fixed Circuit Breaker Installation & Outline Dimensions (Refer to Figures 1, 2)

◆ Drawer-Type Circuit Breaker Installation & Outline Dimensions (Refer to Figures 3, 4, 5, 6, 7, 8, 9)
User Connection Busbar Specifications and Quantity
| Rated Current | External Copper Busbar Specification | Number of Bars per Pole | Rated Current | External Copper Busbar Specification | Number of Bars per Pole |
| 630A | 40×5 | 2 | 2900A | 100×10 | 3 |
| 800A | 50×5 | 2 | 3200A | 120×10 | 3 |
| 1000A | 60×5 | 2 | 3600A | 120×10 | 4 |
| 1250A | 80×5 | 2 | 4000A | 120×10 | 4 |
| 1600A | 100×5 | 2 | 5000A | 120×10 | 5 |
| 2000A | 100×5 | 3 | 6300A | 120×10 | 6 |
| 2500A | 100×5 | 4 | - | - | - |
Frequently Asked Questions (FAQ)
QWhat frame levels are available for the W1 ACB Intelligent Universal Circuit Breaker?
The W1 ACB is available in four frame levels: 2000A, 3200A, 4000A, and 6300A. Each frame level covers a range of rated currents to suit different application requirements in power distribution systems.
QWhat is the rated short-circuit breaking capacity (Icu) of the W1 ACB at 400V?
The rated short-circuit breaking capacity (Icu) varies by frame level: 80kA for the 2000A frame, 100kA for the 3200A and 4000A frames, and 120kA for the 6300A frame — all at 400V.
QWhat installation types are available for the W1 ACB?
The W1 ACB is available in two installation types: Fixed Circuit Breaker and Drawer-Type Circuit Breaker. Each type has specific installation dimensions and busbar connection requirements based on the rated current.
QWhat operating voltages are supported by the W1 ACB's auxiliary components?
The auxiliary components — including the shunt release, closing electromagnet, and motorized operating mechanism — support AC220V, AC380V (50Hz), DC110V, and DC220V. The intelligent controller also supports these same voltage options.
QHow many poles does the W1 ACB support?
The W1 ACB supports both 3-pole and 4-pole configurations. In the type designation, 4-pole models are marked with "4," while 3-pole models have no specific marking for the number of poles.
QWhat copper busbar specifications are recommended for a 6300A rated current?
For a 6300A rated current, external copper busbars with a specification of 120×10mm are recommended, with 6 bars per pole to ensure safe and reliable current distribution.