SZ11,SFZ11 Type 35kV Series On-load Regulator Power Transformer

The SZ11, SFZ11 Type 35kV Series On-load Regulator Power Transformer, complies with the national standards GB 1094 Power Transformers and GB/T 6451 Technical Parameters and Requirements for Three-Phase Oil-Immersed Power Transformers. A series of major reforms in materials, processes, and structures have been adopted, bringing its electrical performance up to the advanced international level of similar products. Featuring high efficiency and low loss, it can save a significant amount of power consumption and operating costs, delivering remarkable social benefits. It is a new product promoted by the state and one of the most popular among users.

    Type & Meaning

    3
    1 Three-Phase Oil-Immersed Transformer
    2 Forced Air Cooling
    3 On-Load Tap-Changing
    4 Performance Level Code
    5 Rated Capacity (kVA)
    6 Voltage Class (kV)

    Product Features

    - Equipped with on-load tap-changing, it meets user voltage requirements, improves power supply quality, and saves energy.
    - The core is made of high-quality high-permeability silicon steel sheets with fully mitered step-lap joints, which reduces the core's no-load loss and no-load current.
    - The high-voltage winding adopts a continuous type, and the low-voltage winding is either continuous or spiral. The ampere-turn distribution is balanced, and the mechanical strength is high. A new insulation structure is applied to the transformer body, enhancing the short-circuit withstand capability.
    - The oil tank is of barrel or bell-jar type, with corrugated walls for an aesthetic and compact appearance as well as high mechanical strength. Precision-machined flanges are used for key connections to prevent leakage.

     product Display

    SFZ11 On-load Regulator Power Transformer
    SZ11,SFZ11 Type On-load Power Transformer right

    Standards

    - GB 1094.1~2-1996 Power Transformers
    - GB 1094.3,5-2003 Power Transformers
    - GB/T 6451-1999 Technical Parameters and Requirements for Three-Phase Oil-Immersed Power Transformers

    Technical Parameters

    Technical Parameters of SZ11-2000~12500/35kV Series Three-Phase Oil-Immersed On-Load Tap-Changing Power Transformers

    Type Voltage Combination Connection Symbol No-Load Loss (kW) Load Loss (kW) Short-Circuit Impedance (%) No-Load Current (%) Weight (kg) Overall Dimensions (mm) Wheelbase (mm)
    High-Voltage (kV) Tap-Changing (%) Low-Voltage (kV) Oil Weight Total Weight Length(L)×Width(W)×Height(H)
    SZ11-1600/35 35
    38.5
    ±3%

    ×2.5
    10.5
    6.3

    11
    Yd11 2.3  18.5  6.5  1450  5050  2850×2050×2300 820×820
    SZ11-2000/35 2.88  20.25  0.8  1600  5900  3020×2250×2650 1070×1070
    SZ11-2500/35 3.4  21.73  0.8  1750  6950  3150×2280×2650 1070×1070
    SZ11-3150/35 4.04  26.01  0.72  1950  7900  3300×2350×2900 1070×1070
    SZ11-4000/35 4.84  30.69  0.72  2250  9100  3350×2500×3000 1070×1070
    SZ11-5000/35 5.8  36  0.68  2500  10900  3500×2650×3050 1070×1070
    SZ11-6300/35 7.04  38.7  7.5  0.68  2650  12500  3800×3150×3300 1070×1070
    SZ11-8000/35 YNd11 9.84  42.75  0.6  3350  15500  4200×3160×3400 1475×1475
    SZ11-10000/35 11.6  50.58  0.6  3750  18000  4500×3200×3500 1475×1475
    SZ11-12500/35 13.68  59.85  0.56  4250  23500  4800×3200×3600 1475×1475
    SZ11-16000/35 16.46  74.02  0.54  6300  26000  4900×3400×3700 1475×1475
    SZ11-20000/35 19.46  87.14  0.54  7500  32500  5000×3500×4000 1475×1475

    Note:
    1.For performance parameters, overall dimensions, and weight data of 35kV class transformers with larger capacities, please consult our company.
    2. For transformers with a capacity of 8000kVA and above, forced air cooling devices can also be provided according to user requirements (type: SFZ11).
    3. The weight and overall dimension data in the table are for reference only; no prior notice will be given for any changes.