SJKM5DC DC Molded Case Circuit Breaker 1500V for Solar Arrays - Top China Suppliers & Factory
Type Designation

| 1 | Manufacturer Code |
| 2 | Molded Case Circuit Breaker |
| 3 | Design Serial Number |
| 4 | PV: Photovoltaic Special | DC: Direct Current Special |
| 5 | Frame Size Rating |
| 6 | Number of Poles |
| 7 | Accessory Code (See Table Below) |
| 8 | Rated Current |
| 9 | Operating Voltage |
| Accessory Code Table: | ||||||||||
| Accessory | None | Alarm Contact | Shunt Release | Shunt+Alarm | Auxiliary Contact | Auxiliary+Alarm | Shunt+Auxiliary | Shunt+Auxiliary+Alarm | Two Auxiliaries | Two Auxiliaries+Alarm |
| Accessory Code | 00 | 08 | 10 | 18 | 20 | 28 | 40 | 48 | 60 | 68 |
Product Display
Technical Parameters
| Product Model | SJKM5DC | |||||||||||||||
| Frame Size Rating | 250 | 315 | 400 | 630 | 800 | |||||||||||
| Rated Current (A) | 63A, 80A, 100A, 125A, 140A, 160A, 180A, 200A, 225A, 250A | 250A, 315A, 350A, 400A | 400A, 500A, 630A | 630A, 700A, 800A | ||||||||||||
| Nominal Insulation Voltage (V) | 1500V | |||||||||||||||
| Rated Impulse Withstand Voltage (KV) | 12KV | |||||||||||||||
| Type | DC | PV | DC | PV | DC | PV | DC | PV | DC | PV | ||||||
| Rated Operating Voltage (V) | 2P Shape | DC250V, DC500V, DC750V, DC1000V, DC1500V | DC250V, DC500V, DC750V, DC1000V, DC1500V | |||||||||||||
| 3P Shape | DC1000V, DC1250V, DC1500V | DC1000V, DC1500V | ||||||||||||||
| Rated Ultimate Short-Circuit Breaking Capacity (KA) | 2P Shape | DC1000V(2P):15 DC1500V(2P):5 |
DC250V,DC500V(2P):50 DC750V,DC1000V(2P):25 DC1500V(2P):7.5 |
DC1000V(2P):15 DC1500V(2P):5 |
DC250V,DC500V(2P):50 DC750V,DC1000V(2P):25 DC1500V(2P):7.5 |
DC250V,DC500V(2P):25 DC750V,DC1000V(2P):15 DC1500V(2P):10 |
DC250V,DC500V(2P):50 DC750V,DC1000V(2P):25 DC1500V(2P):10 |
DC250V,DC500V(2P):25 DC750V,DC1000V(2P):15 DC1500V(2P):10 |
DC250V,DC500V(2P):50 DC750V,DC1000V(2P):25 DC1500V(2P):10 |
DC250V,DC500V(2P):25 DC750V,DC1000V(2P):15 DC1500V(2P):10 |
DC250V,DC500V(2P):50 DC750V,DC1000V(2P):25 DC1500V(2P):10 |
|||||
| 3P Shape | DC1500V(3P):20 | DC1000V,DC1250V,DC1500V(3P):25 | DC1500V(3P):20 | DC1000V,DC1250V,DC1500V(3P):25 | DC1000V(3P):30 DC1500V(3P):25 |
DC1000V(3P):40 DC1500V(3P):30 |
DC1000V(3P):30 DC1500V(3P):25 |
DC1000V(3P):40 DC1500V(3P):30 |
DC1000V(3P):30 DC1500V(3P):25 |
DC1000V(3P):40 DC1500V(3P):30 |
||||||
| Rated Short-Circuit Breaking Capacity (kA) | 2P Shape | 100% Icu | ||||||||||||||
| 3P Shape | ||||||||||||||||
| Connection Mode | 2P Shape (Figure 1), 3P Shape (Figure 2) | 2P Shape (Figure 1), 3P Shape (Figure 3) | ||||||||||||||
| Isolation Function | YES | |||||||||||||||
| Selective Category Cat | A | |||||||||||||||
| Mechanical Life (Cycles) | 20000 | 10000 | ||||||||||||||
| Electrical Life (Cycles) | 1500 | 1000 | 800 | 500 | ||||||||||||
| Flashover Distance (mm) | 2P Shape | ≤50 | ≤100 | ≤50 | ≤100 | ≤100 | ||||||||||
| 3P Shape | 200×73×135 | 270×130×156 | ||||||||||||||
| Overall Dimensions (mm) | 200×107×135 | 310×182×156 | ||||||||||||||
| Reference Ambient Temperature (℃) | ||||||||||||||||
Internal & External Accessories

Function The Alarm Switch features an intelligent alarm system that automatically triggers a fault signal when tripped by overload, short circuit, or external release, while remaining inactive during normal operations - making it ideal for automation system integration.
Tripping Characteristics

Function Equipped with dual-contact auxiliary switches (NO+NC), the SJKM1E ECB provides real-time remote status monitoring and interlocking by reversing contact states during opening/closing operations.
Tripping Characteristics

Function A shunt release is a device that remotely trips a circuit breaker using electric current; it automatically cuts off the signal circuit after the circuit breaker has tripped.
Tripping Characteristics
| Voltage Specification | AC 50Hz: 24V, 110V, 230V, 400V | DC: 24V, 110V, 220V |
| Tripping Characteristics | When the control voltage is between 70% and 110% of the rated value, the shunt release can trip the circuit breaker. |
Outline & Installation Dimensions

| Model Specification | Overall Dimensions (mm) | Mounting Dimension (mm) | ||||||||||||||||||
| L | W | H | L1 | L2 | W1 | H1 | H2 | a | b | 4-Ød | ||||||||||
| 250/2P | 200 | 76 | 135 | 10.5 | 9.5 | 22 | 98 | 26 | / | 161 | 4.5 | |||||||||
| 250/3P | 200 | 107 | 135 | 10.5 | 9.5 | 22 | 98 | 26 | 35 | 161 | 4.5 | |||||||||
| 400/2P | 257 | 140 | 170 | 16 | 10.5 | 30 | 94 | 36 | 43.5 | 197 | 6.5 | |||||||||
| 400/3P | 257 | 184 | 170 | 16 | 10.5 | 30 | 94 | 36 | 43.5 | 197 | 6.5 | |||||||||
| 630/2P | 257 | 140 | 170 | 16 | 10.5 | 30 | 94 | 36 | 43.5 | 197 | 6.5 | |||||||||
| 630/3P | 257 | 184 | 170 | 16 | 10.5 | 30 | 94 | 36 | 43.5 | 197 | 6.5 | |||||||||
| * Conductor Cross-Section | ||||||||||||||||||||
| Rated Current (A) | 63 | 80 | 100 | 125/140 | 160 | 180/200/225 | 250 | 280/300/315 | 350/400 | 500/630 | 700/800 | |||||||||
| Wire Cross-Section (mm²) | 16 | 25 | 35 | 50 | 70 | 90 | 120 | Copper Bar 20×5×2 | Copper Bar 40×5 | Copper Bar 40×8 | Copper Bar 40×5×2 | |||||||||







Claire
Mr.Fu

Claire