SJKM1L Earth Leakage Circuit Breaker ELCB: Reliable Industrial Safety Solution from China Suppliers & Factory
Type Designation

| ① | Manufacturer Code |
| ② | Molded Case Circuit Breaker (MCCB) |
| ③ | Design Serial Number |
| ④ | With Residual Current Protection |
| ⑤ | Frame Size |
| ⑥ | Breaking Capacity: L (Standard) | M (Medium) | H (High) |
| ⑦ | Operation: None (Manual) | Z (Rotary Handle) | D (Motorized) |
| ⑧ | Poles: 3 (3-Pole), 4 (4-Pole) |
| ⑨ | Trip Type & Accessory Code (See Table 1) |
| ⑩ | Application Code: None (Distribution) | 2 (Motor Protection) |
| ⑪ | 4-Pole Code (A/B/C/D for Neutral), 3-Pole: No Code |
| ⑫ | Alarm Module: Ⅰ (Alarm + Trip) | Ⅱ (Alarm Only) |
Notes:
Frame Size: 1N25 (125A), 2N50 (250A), 4N00 (400A), 6N30 (630A), 8N00 (800A)
Frame Size: 1N25 (125A), 2N50 (250A), 4N00 (400A), 6N30 (630A), 8N00 (800A)
Product Display
Trip - Opening Method and Accessory Code
Main Parameters and Technical Performances
| Model | SJKM1LE-125 | SJKM1LE-250 | SJKM1LE-400 | SJKM1LE-630、800 | |||||
| Maximum Rated Current of Shell Frame Grade A | 125 | 250 | 400 | 800 | |||||
| Rated Current In A | 16 20 25 32 40 50 63 80 100 125 |
125 160 180 200 225 250 |
250 315 350 400 |
400 500 630 700 800 |
|||||
| Number of Poles | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | |
| Rated Insulation Voltage Ui V | AC800 | ||||||||
| Rated Working Voltage Ue V | AC400 | ||||||||
| Rated Impulse Withstand Voltage Uimp V | 8000 | ||||||||
| Arc-Quenching Distance mm | 50 | 50 | 100 | 100 | |||||
| Breaking Capacity Icu / Ics | L | M | L | M | L | M | L | M | |
| AC400V | 35 50 | 35 50 | 50 65 | 50 65 | |||||
| AC400V | 22 35 | 25 35 | 35 42 | 35 42 | |||||
| Rated Residual Short-Circuit Making (Breaking) Capacity Icu/4 | 8.75 | 12.5 | 15.75 | 16.25 | |||||
| Rated Residual Operating Current I△n (mA) | Non-delay type | 30/50/100 100/300/500 |
30/50/100 100/300/500 |
100/300/500 | 300/500/1000 | ||||
| Delay type | 100/300/500 | 100/300/500 | 100/300/500 | 300/500/1000 | |||||
| Rated Non-operating Residual Current | 1/2I△n | 1/2I△n | 1/2I△n | 1/2I△n | |||||
| Number of Operating Performances | Energized | 1500 | 1000 | 1000 | 1000 | ||||
| De-energized | 8500 | 7000 | 4000 | 4000 | |||||
| Total number of times | 10000 | 8000 | 5000 | 500 | |||||
| Operating Time of Residual Current Protection | 2I△n | 2I△n | 5I△n | 10I△n | |||||
| Maximum Breaking Time (S) | Non-delay type | 0.2 | 0.1 | 0.4 | 0.04 | ||||
| Delay type | 0.5/1.15/2.15 | 0.35/1/2 | 0.25/0.9/1.9 | 0.25/0.9/1.9 | |||||
Outline and Installation Dimensions
◆ Outline and Installation Dimensions of the Circuit Breaker After Wiring
Circuit breaker rear-panel wiring

| Model | Overall Dimensions (mm) | Installation Dimensions (mm) | |||||||||
| L1 | L2 | L3 | H1 | H2 | a1 | b1 | ΦD | Φd | |||
| 3P | 4P | 3P | 4P | ||||||||
| SJKM1LE-125 | 162 | 132 | 35 | 53 | 93 | 72 | 102 | 90 | 132 | 22 | 5.5 |
| SJKM1LE-250 | 173 | 144 | 35 | 55 | 100 | 87 | 122 | 93 | 144 | 24 | 5.5 |
| SJKM1LE-400 | 267 | 224 | 37 | 48.5 | 108.5 | 124 | 172 | 164 | 224 | 26 | 6.5 |
| SJKM1LE-630/800 | 295 | 243 | 37 | 62 | 62 | 178 | 248 | 158 | 243 | 48 | 7.0 |
◆ Outline and Installation Dimensions of Plug-in Type Rear-panel Wiring

| Model | w | L | A | H1 | G | G1 | a | b | Φd | ||
| 3P | 4P | 3P | 4P | ||||||||
| SJKM1LE-125 | 91 | 125 | 168 | 38 | 50 | 33 | 28 | 60 | 90 | 56 | 6.5 |
| SJKM1LE-250 | 107 | 145 | 186 | 46 | 50 | 33 | 37 | 70 | 105 | 54 | 6.5 |
| SJKM1LE-400 | 149 | 200 | 280 | 55 | 60 | 38 | 46 | 60 | 108 | 129 | 8.5 |
| SJKM1LE-630/800 | 210 | 280 | 305 | 62 | 87 | 60 | 22 | 90 | 162 | 146 | 11 |
◆ Outline and Installation Dimensions of the Circuit Breaker with Front-panel Wiring

Circuit Breaker Front Terminal
| Model | Pole | Overall Dimensions (mm) | Installation Dimensions (mm) | |||||
| L1 | L2 | L3 | L4 | a | b | Φd | ||
| SJKM1LE-125 | 2 | 65 | 151 | 110 | 75 | 129 | 2×Φ4.5 | |
| 3 | 93 | 151 | 110 | 92 | 30 | 129 | 4×Φ4.5 | |
| 4 | 123 | 151 | 110 | 92 | 60 | 129 | 6×Φ4.5 | |
| SJKM1LE-250 | 2 | 75 | 165 | 110 | 90 | 129 | 2×Φ4.5 | |
| 3 | 107 | 165 | 110 | 90 | 35 | 126 | 4×Φ4.5 | |
| 4 | 142 | 165 | 110 | 90 | 70 | 126 | 6×Φ4.5 | |
| SJKM1LE-400 | 3 | 154 | 257 | 146 | 106 | 44 | 194 | 4×Φ4.5 |
| 4 | 198 | 257 | 146 | 106 | 94 | 194 | 6×Φ4.5 | |
| SJKM1LE-630 SJKM1LE-800 |
3 | 210 | 280 | 155 | 116 | 70 | 243 | 4×Φ7 |
| 4 | 280 | 280 | 155 | 116 | 140 | 243 | 6×Φ7 | |
Frequently Asked Questions (FAQ)
What does SJKM1LE stand for in the type designation?
The SJKM1LE designation is a structured code: "SJ" represents the manufacturer code, "KM1" denotes the Molded Case Circuit Breaker (MCCB) series and design serial number, "L" indicates residual current (earth leakage) protection, and "E" identifies the frame size and breaking capacity level. Each segment provides specific information about the product's configuration and capabilities.
What are the available frame sizes for the SJKM1LE series?
The SJKM1LE series is available in five frame sizes: 1N25 (125A), 2N50 (250A), 4N00 (400A), 6N30 (630A), and 8N00 (800A). Each frame size corresponds to a specific maximum rated current and is designed for different load requirements in electrical distribution systems.
What breaking capacity options are available for the SJKM1LE circuit breakers?
The SJKM1LE series offers two breaking capacity levels at AC400V: Standard (L) and Medium (M). For the 125A and 250A models, Icu values are 35kA (L) and 50kA (M). For the 400A, 630A, and 800A models, Icu values are 50kA (L) and 65kA (M). The corresponding Ics values are also available as specified in the technical parameters table.
What residual current (earth leakage) protection settings are available?
The residual operating current (I△n) settings vary by model. For SJKM1LE-125 and -250, non-delay types offer 30/50/100/300/500 mA, while delay types offer 100/300/500 mA. The SJKM1LE-400 supports 100/300/500 mA, and the SJKM1LE-630/800 supports 300/500/1000 mA. The non-operating residual current threshold is 1/2 I△n for all models.
What operation types are supported for the SJKM1LE series?
The SJKM1LE circuit breakers support three operation types: standard manual operation (no suffix), rotary handle operation (suffix Z), and motorized operation (suffix D). The motorized option allows for remote or automated switching, making it suitable for applications where manual access is limited or automatic control is required.
What wiring configurations are available for the SJKM1LE circuit breakers?
The SJKM1LE series supports three wiring configurations: standard rear-panel wiring, plug-in type rear-panel wiring, and front-panel wiring. Each configuration has specific outline and installation dimensions provided in the technical tables, covering both 3-pole and 4-pole versions. Refer to the dimension tables and diagrams in this page for exact measurements per model.