Introducing the SJKM1 Moulded Case Circuit Breaker (MCCB), a top-tier solution for AC 50/60Hz power systems operating up to 690V and 1250A. As a reliable choice among China suppliers, this MCCB offers exceptional protection against overloads, short circuits, and undervoltage, making it perfect for distribution networks. With configurations available for frame sizes up to 400A, it is also capable of safeguarding motors effectively. Crafted in compliance with IEC 60947-2 and GB14048.2 standards, the SJKM1 MCCB ensures safe and efficient power distribution alongside optimal equipment protection. Designed for durability, it supports infrequent switching and motor starts, making it an ideal fit for industrial and commercial applications sourced from trusted factories in China.

,

    Type Designation

    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-5
    No. Designation Details
    Manufacturer Code
    Molded Case Circuit Breaker Code
    Design Code
    Frame Size
    Short-Circuit Breaking Capacity Level 4
    Operation method 3
    Number of Poles 2
    Trip Unit Method & File Code
    Function Code 1
    Type code(See Table 1 for N-pole of four-pole,no code for three-pole)
    Notes:

    1. There is no code for distribution circuit breakers; for motor - protection circuit breakers, use 2 to represent.

    2. Number of poles: 2 for two - pole; 3 for three - pole; 4 for four - pole.

    3. For handle - direct operation: use D to represent for power - distribution use, and use Z to represent for conversion - locking use.

    4. For economy type: represent with E; for standard type: represent with M; for higher - reliability type: represent with H; for high - breaking type: represent with L.

    Product Display

    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-(1)
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-(2)
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-(3)
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-(4)

    N - Pole Type Code

    Type Code Description
    Type A No over - current release element is installed on the N - pole, and the N - pole is always connected, and does not close and open together with the other three poles.
    Type B No over - current release element is installed on the N - pole, and the N - pole closes and opens together with the other three poles (the N - pole closes first and opens later).
    Type C An over - current release element is installed on the N - pole, and the N - pole closes and opens together with the other three poles (the N - pole closes first and opens later).
    Type D An over - current release element is installed on the N - pole, and the N - pole is always connected, and does not close and open together with the other three poles.

    Release Modes and Accessory Codes

    Accessory Name Without Accessory Alarm Contact Shunt Release Auxiliary Contact Under - voltage Release Shunt Release Auxiliary Contact Two - group Auxiliary Contacts Shunt Release Under - voltage Release Auxiliary Contact Under - voltage Release
    Release Mode Instantaneous Code 200 208 210 220 230 240 250 260 270
    Compound Code 300 208 310 320 330 340 350 360 370

    (Continued from the previous table)

    Accessory Name Shunt Release Alarm Contact Auxiliary Contact Alarm Contact Under - voltage Release Alarm Contact Shunt Release Auxiliary Contact Alarm Contact Two - group Auxiliary Contact Alarm Contact Auxiliary Contact Under - voltage Release Alarm Contact
    Release Mode Instantaneous Code 218 228 238 248 268 278
    Compound Code 318 328 338 348 268 378
    Notes:

    1) 200 indicates the circuit breaker body with only an electromagnetic release; 300 indicates the circuit breaker body with thermal and electromagnetic releases.

    2) For the two - level products SJKM1 - 125 and SJKM1 - 250, only 210, 310, 220, 320, 230, and 330 are available.

    Normal Operating Conditions and Installation Conditions

    Ambient temperature: The circuit breaker can operate normally at an ambient temperature range of -5°C to +40°C (except for special orders).
    Altitude: The altitude of the installation site of the circuit breaker shall not exceed 2000m.
    Pollution degree: The pollution degree of the circuit breaker is Grade 3.
    Installation category: The installation category of the circuit breaker is Category III.
    Installation position: The circuit breaker can be installed horizontally, vertically, or flat, without reducing its electrical performance.

    Main Parameters and Technical Performances

    Circuit Breaker Model SJKM1-63 SJKM1-125 SJKM1-250 SJKM1-400 SJKM1-630 SJKM1-800 SJKM1-1250
    Pole Number 3 4 3 2 4 3 2 4 3 4 3 4 3 4 3 4
    Rated Current In A 10 16 20 25 32 40 50 63 16 20 25 32 40 50 63 80 100 125 100 125 140 160 180 200 225 250 225 250 315 350 400 400 500 630 630 700 800 800 1000 1250
    Rated Insulation Voltage Ui (V) 690 1000 1000 1000 1000 1000 1000
    Rated Impulse Withstand Voltage Uimp V 6000 - - - - 8000 -
    Rated Working Voltage Ue V 400 AC400/690 AC400/690 AC400/690 AC400/690 AC400/690 AC400/690
    Breaking Capacity Level L M L M H L M H L M H L M H H H
    Ultimate Short-Circuit Breaking Capacity Icu (kA) (0-tCO) 400V 25 50 35 50 85 35 50 85 50 65 100 50 65 100 100 100
    690V - - - - 25 - - 25 - - 30 - - 30 - 25
    Service Short-Circuit Breaking Capacity Ics (kA) (0-tCOtCO) 400V 18 30 25 35 50 25 35 65 35 50 65 35 50 65 65 50
    690V - - - - 15 - - 15 - - 20 - - 20 - 20

    Appearance and Installation Dimensions

    ◆ Appearance and installation dimensions of the fixed - type front - connected and rear - connected wiring

    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (1)SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (2)

    ◆ Appearance and installation dimensions of fixed - type front and rear wiring

    Model Number Overall dimensions (mm) Mounting Dimensions (mm) Dimensions for Rear Terminal Wiring (mm)
    L L1 W H H1 H2 a b φd al b1 d1 H3 H4
    SJKM1-63L 3 135 21 76 88 72 19 25 117 4 25 117 18 52 75
    SJKM1-63M - - - - 97 82 28 - - - - - - - -
    SJKM1-63 4 - - 103 - - - - - - - - - - -
    SJKM1-125L - 150 51 92 86 68 24 30 129 4.5 30 132 22 65 100
    SJKM1-125M 3 - - - 104 86 23 - - - - - - - -
    SJKM1-125H - - - - - - - - - - - - - - -
    SJKM1-125 2 - - 65 - - - --- - - - - - - -
    4 122 30
    SJKM1-250L - 165 64 107 108 87 25 35 126 5.5 35 144 24 70 110
    SJKM1-250M 3 165 - 107 124.5 104 24.5 - - - - - - - -
    SJKM1-250H - - - - - - - - - - - - - - -
    SJKM1-250 2 - - 75 - - - -- - - - - - - -
    4 142 -
    SJKM1-400 3 257 105 149 150 100 36.5 44 195 6.5 44 225 32 70 120
    4 198
    SJKM1-630 3 270 118 182 155 108 41 58 200 7 58 234 40 70 120
    4 240
    SJKM1-800 3 282 102 210 158 103 34.5 70 243 7 70 243 48 70 125
    4 280
    SJKM1-1250 3 406 104 210 190 140.5 58.5 70 375 10 - - - - -
    Handle H W Protrusion in the middle L W H
    63 17 13.5 63 44 22 5.5
    125 19 13 125 51 23 5.5
    250 22 12.5 250 52 23 4
    400 43.5 33.5 400 89.5 65 7
    630 44 33.5 630 90 65.5 7
    800 40 33.5 800 105 61 5
    1250 51 41 1250 100 78 16

    ◆ Appearance and installation dimensions of the plug - in type front - connected wiring

    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (3)

    ◆ Appearance and installation dimensions of plug - in type rear - panel wiring

    Model W L A H1 G G1 a b d
    SJKM1-63 75 135 18 28 17 15 50 60 6
    SJKM1-125 92 170 38 50 33 28 60 56 6.5
    SJKM1-250 107 186 46 50 33 40 70 54 7
    SJKM1-400 144 280 50 60 40 48 88 143 9
    SJKM1-630 182 300 65 60 40 53 100 123 9
    SJKM1-800 212 298 57 100 43 129 140 143 9

    ◆ Outline and Installation Schematic Diagram of Withdrawable Device

    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (4)

    ◆ Outline and Installation Dimensions of Withdrawable Device

    Model pole overall dimensions installation dimensions
    L1 L2 L3 H1 H2 H3 W1 W2 φd1 A B φd2
    SJKM1-400/M 3P 310 339 203 253 17.5 77 48 223 φ11 96 134 φ6.5
    4P 310 339 203 253 17.5 77 48 271 φ11 144 134 φ6.5
    SJKM1-630/M 3P 341 381 211 282 17.5 92 58 253 φ13 116 140 φ6.5
    4P 341 381 211 282 17.5 92 58 311 φ13 174 140 φ6.5
    SJKM1-800/M 3P 367 410 241 238 26 73 70 289 φ13 140 131 φ6.5
    4P 367 410 241 238 26 73 70 359 φ13 210 131 φ6.5

    Frequently Asked Questions (FAQ)

    What are the normal operating temperature conditions for SJKM1 MCCBs?
    The SJKM1 moulded case circuit breaker operates normally within an ambient temperature range of -5°C to +40°C. For requirements outside this range, special customized orders are available.
    What is the maximum installation altitude for the SJKM1 circuit breaker?
    The installation site altitude for the SJKM1 circuit breaker should not exceed 2000 meters to ensure standard technical performance.
    Can the SJKM1 circuit breaker be installed horizontally?
    Yes. The SJKM1 series can be installed vertically, horizontally, or flat without reducing its electrical performance.
    What is the difference between N-pole Type A and Type B configurations?
    Type A has no over-current release element on the N-pole, is always connected, and does not open/close dynamically with the other three poles. Type B also has no over-current release, but it closes and opens together with the other three poles (closes first, opens later).
    What do the release mode codes 200 and 300 stand for?
    Code 200 indicates a circuit breaker body equipped only with an electromagnetic release, whereas code 300 represents a configuration with both thermal and electromagnetic releases.
    What is the pollution degree rating and installation category of this MCCB?
    The SJKM1 circuit breaker has a Pollution Degree of Grade 3 and belongs to Installation Category III.