Intelligent Wireless Automatic Gas Fire Extinguishing Device - Perfluorohexanone Series by Leading China Suppliers & Factory
Type Designation

Product Name: Intelligent Wireless Automatic Gas Fire Extinguishing Device
Product Model: YF□Q-MR1
Fire Suppressant: Perfluorohexanone
Product Type: Stand-alone Type
Trigger Mode: Electric Start + Thermal Start
Installation Method: Nut Press Fit
Product Display
Product Features
- ✔It consists of a wireless alarm control unit and a perfluorohexanone fire extinguishing device.
- ✔Simultaneous online detection of wire temperature, ambient temperature, and smoke to prevent electrical fire hazards.
- ✔Equipped with various communication interfaces such as RS485, 4G, and Lora.
- ✔Functions include real-time data collection, historical curves, event recording, and trend analysis.
- ✔The split-type product design allows for easy replacement of the extinguishing unit by the user after deployment, enabling multiple reuses and reducing operational costs.
Technical Parameters
| Function Configuration | YF0.18Q/MR1 | YF0.3Q/MR1 | YF0.5Q/MR1 | YF1.0Q/MR1 | YF1.5Q/MR1 |
| Agent Quantity | 180g | 300g | 500g | 1000g | 1500g |
| Protected Space | ≤0.3m³ | ≤0.6m³ | ≤1m³ | ≤2m³ | ≤3m³ |
| Dimensions | 145×80×20mm | 145×125×20mm | 63×63×362mm | 63×63×362mm | 63×63×442mm |
| Energy Storage Method | Non-stored Pressure Type | ||||
| Application Method | Total Flooding or Local Flooding | ||||
| Discharge Time | ≤14s | ||||
| Discharge Delay Time | ≤0.5s | ||||
| Nozzle Thermal Clearance | Temperature at 400mm from nozzle ≤75℃ | ||||
| Surface Temperature of Enclosure | ≤75℃ | ||||
| Extinguishing Density | 100g/m³ ~ 130g/m³ | ||||
| Agent Service Life | 6 Years | ||||
| Protected Area Requirements | Protected area should be relatively enclosed | ||||
| Installation Method | Screw Fixation | ||||
| Operating Environment | -40 ~ +85℃ <95%RH | ||||
| Activation Method | Logical activation (temperature exceeds 100℃ and smoke detected simultaneously) | ||||
| Remote activation (via host or cloud platform) | |||||
| Manual forced start (emergency button, press and hold for 3 seconds) | |||||
| Over-temperature activation (when any point of thermal detection line exceeds 170℃) | |||||
Performance Analysis Table of Different Agents
| Product Comparison | Non-pressurized Perfluorohexanone Device | Ultra-fine Dry Powder | Hot Aerosol | HFC-227ea |
| Extinguishing Concentration | 4%–6% | 120g/m³ | 100g/m³ | 6.7%–8.7% |
| Harmful Concentration | 10% | Strong Asphyxiation | Strong Asphyxiation | 9% |
| Extinguishing Mechanism | Heat absorption & Chemical inhibition | Smothering & Oxygen reduction | Isolation, smothering & Heat absorption | Chemical inhibition |
| Pressurized? | No | No | No | Yes |
| Safe for Occupied Spaces? | Yes | No | No | No |
| Suitable for Electrical Equipment | Yes | No | Yes | Yes |
| Residue | None | Heavy powder residue | Some powder, corrosive | None |
| Safety Risks | None | Agent can settle | High heat released during reaction | Pressure leakage risk |
| Environmentally Friendly | Yes | No | No | No |
Frequently Asked Questions
Q What fire suppressant is used in the YF-MR1 series device?
The YF-MR1 series uses Perfluorohexanone (also known as Novec 1230 equivalent) as the fire suppressant. It is a clean, environmentally friendly agent that leaves no residue and is safe for use in occupied spaces.
Q How does the YF-MR1 device detect and activate in case of fire?
The device supports four activation methods: logical activation (simultaneous detection of temperature exceeding 100℃ and smoke), remote activation via host or cloud platform, manual forced start by pressing the emergency button for 3 seconds, and over-temperature activation when any point on the thermal detection line exceeds 170℃.
Q What is the service life of the fire suppression agent?
The fire suppression agent has a service life of 6 years. Additionally, the split-type design allows users to easily replace the extinguishing unit after deployment, enabling multiple reuses and reducing long-term operational costs.
Q What protected space volumes are covered by the different models?
The models cover a range of protected spaces: YF0.18Q/MR1 covers up to 0.3m³, YF0.3Q/MR1 up to 0.6m³, YF0.5Q/MR1 up to 1m³, YF1.0Q/MR1 up to 2m³, and YF1.5Q/MR1 up to 3m³. The protected area should be relatively enclosed for optimal effectiveness.
Q Is the YF-MR1 device safe for electrical equipment and human occupancy?
Yes. The Perfluorohexanone agent is electrically non-conductive, leaves no residue, and has a harmful concentration threshold of 10% — well above its extinguishing concentration of 4%–6%, making it safe for use in spaces with electrical equipment and in occupied environments.
Q What communication interfaces does the wireless alarm control unit support?
The wireless alarm control unit supports multiple communication interfaces including RS485, 4G, and LoRa, allowing seamless integration with building management systems, cloud platforms, and remote monitoring solutions. It also provides real-time data collection, historical trend analysis, and event recording.







Claire
Mr.Fu

Claire