GN30-12(D) Rotary Indoor High-Voltage Disconnector
Type & Meaning

| 1 | Disconnector |
| 2 | Indoor type |
| 3 | Design serial number |
| 4 | Rated voltage |
| 5 | With earthing device |
| 6 | Rated current |
| 7 | Rated short-time withstand current (4s) |
Normal Service Conditions
● Altitude: ≤ 1000 m.
● Ambient air temperature: upper limit +40℃; lower limit -10℃.
● Relative humidity: daily average ≤ 95%; monthly average ≤ 90%.
● Seismic intensity: ≤ Grade 8.
● Locations free from severe dust, chemical corrosion, and explosive substances.
● Locations free from frequent severe vibration.
product Display
Technical Parameters
| Parameters | GN30-12/400-12.5 | GN30-12/630-20 | GN30-12/1000-31.5 | GN30-12/1250-31.5 | GN30-12/2000-31.5 | GN30-12/3150-31.5 | |
| GN30-12D/400-12.5 | GN30-12D/630-20 | GN30-12D/1000-31.5 | GN30-12D/1250-31.5 | GN30-12D/2000-31.5 | GN30-12D/3150-31.5 | ||
| Rated Voltage (kV) | 12 | ||||||
| Maximum Voltage (kV) | 11.5 | ||||||
| Rated Current (A) | 400 | 630 | 1000 | 1250 | 2000 | 3150 | |
| Thermal Withstand Current (kA) | 12.5 | 20 | 31.5 | ||||
| Thermal Withstand Duration (s) | 4 | ||||||
| Rated Peak Withstand Current (kA) | 31.5 | 50 | 80 | ||||
| Rated Insulation Level | Lightning Impulse Withstand Voltage (kV) | 75 | |||||
| 1min Power Frequency Withstand Voltage (kV) | 42 | ||||||
Outline and Installation Dimension

| Model | L | L1 | L2 | A | D | n | B | C |
| GN30-12/630 | 210 | 680 | 726 | 820 | 0 | 2 | 45 | 550 |
| 230 | 720 | 766 | 860 | 0 | 2 | 45 | ||
| 250 | 760 | 806 | 900 | 0 | 2 | 45 | ||
| GN30-12/1000, 1250 | 210 | 680 | 726 | 820 | 40 | 4 | 80 | 575 |
| 230 | 720 | 766 | 860 | 40 | 4 | 80 | ||
| 250 | 760 | 806 | 900 | 40 | 4 | 80 |

| Model | L | L1 | L2 | A | D | n | B |
| GN30-12D/630 | 210 | 680 | 726 | 820 | 0 | 2 | 45 |
| 230 | 720 | 766 | 860 | 0 | 2 | 45 | |
| 250 | 760 | 806 | 900 | 0 | 2 | 45 | |
| GN30-12D/1000, 1250 | 210 | 680 | 726 | 820 | 40 | 4 | 80 |
| 230 | 720 | 766 | 860 | 40 | 4 | 80 | |
| 250 | 760 | 806 | 900 | 40 | 4 | 80 |
Main Structure and Working Principle
The GN30-12 series disconnector is a new rotary-type disconnector. Its main body is fixed to the upper and lower planes of the base frame via two sets of insulators, separated completely by a partition plate mounted on the base. Opening and closing operations are achieved by rotating the contact blade.
The GN30-12D variant adds an earthing switch to meet different switchgear requirements. With contacts installed on both upper and lower planes, live and non-live parts are fully isolated inside the switchgear, ensuring absolute safety for maintenance personnel.
The conductive part consists mainly of contact blades and contacts. Each blade, made of two copper plates fixed inside a rotating porcelain bushing with additional magnetic locking plates, has enhanced rigidity and excellent dynamic and thermal stability under short-circuit currents.
Ball-point contact between blades and contacts reduces assembly difficulty and ensures reliable connection. The switch can be operated with JS×GN-12 or CS6-2 operating mechanisms, or with custom-designed mechanisms.







Claire