Leave Your Message
Products Categories
Featured Products

Compact VSY2-12GD High Voltage Vacuum Circuit Breaker - China Suppliers & Factory for 12kV Power Distribution

Introducing the VSY2-12GD, a state-of-the-art compact three-position high-voltage vacuum circuit breaker specifically engineered for 12kV power distribution systems. Manufactured by trusted China suppliers, this innovative device integrates a disconnector, load switch, and earthing switch within a single unit. Its highly insulated vacuum arc-extinguishing structure guarantees exceptional electrical performance and reliability, As a product of a leading factory, the VSY2-12GD is designed with complete mechanical interlocks, ensuring compliance with switchgear five-prevention requirements, thereby enhancing operational safety. This circuit breaker supports both manual and motorized operations, providing flexibility for various applications. Additionally, it features a visible break after opening, stable short-circuit protection, and impressive long mechanical endurance, Thanks to its compact size, lightweight design, and versatile installation options, the VSY2-12GD is the ideal solution for compact switchgear applications, making it a preferred choice for professionals seeking high-quality equipment in the power distribution sector. Choose the VSY2-12GD for reliable performance and safety in your electrical systems

    Main Features

    Adopts vacuum arc-extinguishing composite insulation structure, featuring high insulation level and excellent electrical performance.
    Integrates disconnector, load switch and earthing switch in one unit, featuring compact structure, small size and light weight.
    Flexible installation methods, with optional operation modes: manual, motorized, and manual closing & electrical opening.
    Adopts rotary disconnector with visible break after opening.
    The load switch equipped with fuses has short-circuit protection function and can replace conventional circuit breakers.
    Mechanical interlocks are set between the disconnector, load switch and earthing switch to meet the "five-prevention" requirements of switchgear.

    Technical Parameters

    No. Name Unit Load Switch Combined Electrical Apparatus
    1 Rated Frequency Hz 50 50
    2 Rated Voltage kV 12 12
    3 1min Power Frequency Withstand Voltage kV 42kV between phases, to ground and at vacuum break / 48kV at isolation break Same as left
    4 Rated Lightning Impulse Withstand Voltage (Peak) kV 75kV between phases, to ground and at vacuum break / 85kV at isolation break Same as left
    5 Rated Current A 630 Maximum rated current of fuse: 125, 200
    6 Rated Short-circuit Breaking Current kA - 31.5
    7 Rated Active Load Breaking Current A 630 -
    8 Rated No-load Transformer Breaking Current - 63 -
    9 Rated Closed-loop Breaking Current A 630 -
    10 Rated Short-time Withstand Current (4s) kA 25 -
    11 Rated Peak Withstand Current kA 63 -
    12 Rated Short-circuit Making Current (Peak) kA 50 50
    13 Rated Transfer (Make) Current A 1700 (3150) Same as left
    14 Mechanical Endurance Times 10000 Same as left

    Product Display

    VSY2-12GD Miniaturized High Vlotage Vacuum Circuit Breaker inside
    VSY2-12GD Miniaturized High Vlotage Vacuum Circuit Breaker

    Outline and Installation Dimension

    VSY2-12GD Miniaturized Three-Position HV Vacuum Circuit Breaker inside view

    Outline Dimension Drawing of VSY2-12GD Front Mounting & Right Operation

    ? Frequently Asked Questions
    Q1 What is the rated voltage of the VSY2-12GD vacuum load switch?
    The VSY2-12GD has a rated voltage of 12 kV, making it suitable for medium-voltage distribution systems operating at this voltage level. Both the load switch and combined electrical apparatus versions share the same rated voltage specification.
    Q2 What are the available operation modes for the VSY2-12GD?
    The VSY2-12GD supports three flexible operation modes: manual operation, motorized operation, and a combined mode featuring manual closing with electrical opening. This flexibility makes it adaptable to a wide range of installation environments and automation requirements.
    Q3 Does the VSY2-12GD meet "five-prevention" switchgear requirements?
    Yes. Mechanical interlocks are implemented between the disconnector, load switch, and earthing switch to fully comply with the "five-prevention" safety requirements of switchgear, preventing misoperation and ensuring safe switching sequences.
    Q4 Can the VSY2-12GD replace conventional circuit breakers?
    Yes. When the load switch is equipped with fuses, the VSY2-12GD gains short-circuit protection functionality. The combined electrical apparatus version has a rated short-circuit breaking current of 31.5 kA, enabling it to replace conventional circuit breakers in many distribution applications.
    Q5 What is the mechanical endurance life of the VSY2-12GD?
    The VSY2-12GD is rated for 10,000 mechanical operations, ensuring a long service life with reliable performance. This applies to both the load switch and combined electrical apparatus configurations.
    Q6 What insulation withstand voltages does the VSY2-12GD support?
    The VSY2-12GD provides robust insulation performance. It withstands 42 kV (1-minute power frequency) between phases, to ground, and at the vacuum break, and 48 kV at the isolation break. For lightning impulse, it withstands 75 kV between phases and at the vacuum break, and 85 kV at the isolation break.