Leave Your Message
Products Categories
Featured Products

China YB□-12 Prefabricated Transformer Substation - 50-1600kVA Power Distribution Solutions from Reliable Suppliers & Factory

The YB□-12 prefabricated substation is a reliable solution offered by top China suppliers, designed to meet the needs of 6-10kV networks with capacities ranging from 50 to 1600kVA. This high-quality substation features a robust 630A current rating, a 20kA short-circuit withstand capability, and an IP23 protection rating, ensuring durability and performance in various settings. With an operating temperature range of -25°C to +40°C, it is perfectly suited for urban grids, industrial parks, and construction sites, Designed for compactness and compliance with GB17467 standards, this prefabricated substation integrates high voltage (HV) and low voltage (LV) equipment alongside oil and dry-type transformers. The YB□-12 supports both ring-network and terminal power modes, making it versatile enough for different applications. Additionally, it is built with seismic resistance to withstand harsh environmental conditions, making it an excellent choice for customers seeking reliable substations from a reputable factory

    Type Designation
    YB-Prefabricated-Transformer-Substation-10
    1 Prefabricated Substation
    2 Structural Feature: P-Triangular Layout; M- Rectangular Layout
    3 Design Serial Number
    4 Rated Voltage on High-Voltage Side (kV)
    5 Rated Voltage on Low-Voltage Side (kV)
    6 Rated Capacity of Transformer (kVA)
    Operating Conditions
    • Altitude: ≤ 1000m
    • Environmental temperature: -25℃ ~ +40℃, (highest monthly average temperature +30℃, highest annual average temperature +20℃)
    • Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%
    • Seismic horizontal: horizontal acceleration of 0.4m/s², vertical acceleration of 0.15m/s²
    • The installation location has no severe impact, no serious pollution or chemical corrosion, and no conductive dust explosion hazard in Egypt
    📌 Note: If ordering this product exceeds the above conditions, please consult with our company.
    Product Display
    YB-Prefabricated-Transformer-Substation-(1)
    YB-Prefabricated-Transformer-Substation-(2)
    YB-Prefabricated-Transformer-Substation-(3)
    YB-Prefabricated-Transformer-Substation-(4)
    YB-Prefabricated-Transformer-Substation-(5)
    YB-Prefabricated-Transformer-Substation-(6)
    Technical Parameters
    No. Name Unit High-Voltage Equipment Transformer Low-Voltage Equipment
    1 Rated Voltage kV 6/10 60/0.4   10/0.4 0.4
    2 Rated Capacity kVA 50~1600
    3 Rated Current A 200, 400, 630 100~3200
    4 Rated Short-Circuit Breaking Current A Load switch: 400-600 15~63kA
    kA Composite switch: Depends on fuse
    5 Rated Short-Time Withstand Current kA 16, 20 (4S) 15 (1s)
    30 (1s)
    6 Rated Peak Withstand Current kA 31.5, 50 30
    63
    7 Power-Frequency Withstand Voltage (1min) kV Relative-to-ground & phase-to-phase: 32/42 25/35 (oil immersed) ≤0.3, 2
    Isolation gap: 36/48 20/28 (dry type) >0.3, 2.5
    8 Lightning Impulse Withstand Voltage (Peak) 0.88 kV Relative-to-ground & phase-to-phase: 60/75 60/75
    Isolation gap: 70/85
    9 Enclosure Protection Level
    10 Noise Level dB IP23
    11 Applicable Standards GT/T 17467 "Prefabricated High/Low-Voltage Substations" 55
    DL/T 537 "Technical Conditions for Ordering 6-35kV Box type Substations"
    ⚠️ Note: For transformers with a capacity below 200kVA, items 5 & 6 are not required.
    Installation Dimensions Diagram
    YB-12-3
    • 1. Roof
    • 2. Louvered Vent
    • 3. External Metering Box
    • 4. Lifting Ring
    • 5. Channel Steel Base Frame
    • 6. Door
    • 7. Strip Brick / Brick-Pattern Cladding
    • 8. Concrete Foundation
    • 9. Foundation Ventilation Opening
    📌 Note: A and B are the external dimensions of the substation base.
    Ordering Notice

    Product operating site and special requirements:

    • 1 Provide product ordering drawings, which should include wiring diagrams and indicate transformer capacity, main component model specifications, distribution branch circuits, and capacity.
    • 2 When it is necessary to configure electric energy metering and reactive power automatic compensation devices, the requirements for the configuration of the metering meter and transformer should be provided, and the capacity of the compensation capacitor should be indicated.
    • 3 Specify the requirements for surface treatment of the product.
    Frequently Asked Questions
    Q What is a YB-type prefabricated transformer substation?
    A YB-type prefabricated transformer substation is a compact, factory-assembled power distribution unit that integrates high-voltage switchgear, a transformer, and low-voltage distribution equipment within a single enclosure. It is designed for easy installation and reliable power supply in various applications.
    Q What are the available layout types for the YB prefabricated substation?
    The YB prefabricated substation is available in two structural layout types: P (Triangular Layout) and M (Rectangular Layout), allowing flexibility to suit different installation site requirements.
    Q What is the rated transformer capacity range for this substation?
    The rated transformer capacity ranges from 50 kVA to 1600 kVA, making it suitable for a wide range of power distribution needs from small commercial facilities to larger industrial projects.
    Q What are the operating altitude and temperature requirements?
    The YB prefabricated substation is designed for altitudes up to 1000m and can operate in environmental temperatures ranging from -25℃ to +40℃. If your installation site exceeds these conditions, please consult with our company for customized solutions.
    Q What information is required when placing an order?
    When ordering, please provide: product ordering drawings with wiring diagrams, transformer capacity and main component model specifications, distribution branch circuits and capacity, requirements for electric energy metering and reactive power compensation devices, and surface treatment requirements.
    Q What standards does the YB prefabricated substation comply with?
    The YB prefabricated substation complies with GT/T 17467 "Prefabricated High/Low-Voltage Substations" and DL/T 537 "Technical Conditions for Ordering 6-35kV Box Type Substations", ensuring high quality and safety standards.