China VSY1-12 12kV Mounted Vacuum Circuit Current Breaker VCB - Reliable Suppliers and Factory Solutions
Type Designation
| Brand: | MINGRI |
| Product Name: | Three-Position Vacuum Circuit Breaker |
| Model: | VSY1-12 |
| Rated Voltage: | 12kV |
| Rated Current: | 630A |
| Peak Withstand Current: | 20KA |
| Energy Storage Time: | ≤15S |
| Operating Temperature: | -10℃ - 40℃ |
Normal Use Environment
Suitable for ambient temperatures from -15°C to +40°C and altitudes up to 1000m (with adjustable insulation for higher elevations). Withstands high humidity (95% daily, 90% monthly averages) and seismic activity up to intensity 8. Designed for use in environments free from explosion, severe pollution, chemical corrosion, and excessive vibration.
Technical Parameters
| No. | Item | Unit | Value |
| 1 | Rated Voltage | kV | 40.5 |
| 2 | Rated Current | A | 1250 / 1600 / 2000 |
| 3 | Rated Short-Circuit Breaking Current | kA | 31.5 |
| 4 | Rated Peak Withstand Current | kA | 80 |
| 5 | Rated Short-Time Withstand Current | kA | 31.5 |
| 6 | Rated Short-Circuit Making Current | kA | 80 |
| 7 | Rated Single Capacitor Bank Breaking Current | A | 630 |
| 8 | Rated Back-to-Back Capacitor Bank Breaking Current | A | 400 |
| 9 | Rated Short-Circuit Current Breaking Operations | time | 20 |
| 10 | Rated Operating Sequence | O-0.3s-CO-180s-CO | |
| 11 | Rated Lightning Impulse Withstand Voltage (Peak) | kV | 185 |
| 12 | Rated Short-Time Power-Frequency Withstand Voltage (1min) | kV | 95 |
| 13 | Closing Time | ms | 65±15 |
| 14 | Opening Time | ms | 40±15 |
| 15 | Mechanical Life | time | 10000 |
| 16 | Rated Voltage of Energy Storage Motor | V | AC220; DC220, 110 |
| 17 | Energy Storage Time | s | ≤15 |
| 18 | Rated Voltage of Closing Solenoid | V | AC220; DC220, 110 |
| 19 | Rated Voltage of Opening Solenoid | V | AC220; DC220, 110 |
| 20 | Rated Current of Auxiliary Switch | A | AC10, DC5 |
Product Display
Outline and Installation Dimension
Frequently Asked Questions
What is the rated voltage of the VSY1-12 Three-Position Vacuum Circuit Breaker?
The VSY1-12 has a rated voltage of 12kV, making it suitable for medium-voltage distribution systems in industrial and utility applications.
What are the ambient temperature and altitude requirements for the VSY1-12?
The breaker is designed for ambient temperatures ranging from -15°C to +40°C and altitudes up to 1000m. For higher altitudes, insulation adjustments can be made to ensure safe operation.
What is the mechanical life expectancy of the VSY1-12 vacuum circuit breaker?
The VSY1-12 is rated for a mechanical life of 10,000 operating cycles, ensuring long-term reliability and reduced maintenance requirements.
What control voltages are supported for the closing and opening solenoids?
Both the closing and opening solenoids support AC220V and DC220V/110V, providing flexible integration with various control systems.
Is the VSY1-12 suitable for use in chemically corrosive or explosive environments?
No. The VSY1-12 is designed for environments free from explosion hazards, severe pollution, chemical corrosion, and excessive vibration. It should not be installed in such conditions without additional protective measures.
What is the energy storage time for the VSY1-12 circuit breaker?
The energy storage time is ≤15 seconds, ensuring rapid readiness for operation after each charge cycle. The energy storage motor supports AC220V and DC220V/110V supply voltages.