China VSB-12 Indoor High-Voltage Vacuum Circuit Breaker Suppliers - Reliable Factory for 12kV Power Systems
Type Designation
| Brand: | MINGRI |
| Product Name: | High-Voltage Vacuum Circuit Breaker |
| Model: | VSB-12 |
| Rated Voltage: | 12kV |
| Rated Current: | 63A |
| Rated Frequency: | 50Hz |
| Altitude: | ≤1000 meters |
| Mechanical Life: | 20,000 operations |
Technical Parameters
| No. | Item | Unit | Value | |||
| 1 | Rated Voltage | kV | 12 | |||
| 2 | Maximum Operating Voltage | kV | 12 | |||
| 3 | Rated Current | A | 630 1250 |
630 1250 1600 2000 2500 3150 |
1250 1600 2000 2500 3150 4000 |
|
| 4 | Rated Short-Circuit Breaking Current (Rated Short-Time Withstand Current - RMS Value) | kA | 20/25 | 31.5 | 40 | |
| 5 | Rated Short-Circuit Making Current (Peak) | kA | 50/63 | 80 | 100 | |
| 6 | Rated Peak Withstand Current (Rated Peak Withstand Current - Peak) | kA | 50/63 | 80 | 100 | |
| 7 | 4S Rated Short-Circuit Withstand Voltage | kA | 20/25 | 31.5 | 40 | |
| 8 | Rated Insulation Level | Power-Frequency Withstand Voltage (1min) (Before and After Rated Breaking) | kV | Phase-to-Earth 42 (Across Isolating Distance 48) | ||
| Impulse Withstand Voltage (Before and After Rated Breaking) / Rated Lightning Impulse Withstand Voltage (Peak) | Phase-to-Earth 75 (Across Isolating Distance 85) | |||||
| 9 | Rated Short-Time Withstand Current Duration | s | 4 | |||
| 10 | Rated Operating Sequence | O-0.3s-CO-180s-CO | ||||
| 11 | Mechanical Life | time | 20,000 | |||
| 12 | Rated Short-Circuit Current Breaking Operations | time | 50 | |||
| 13 | Operating Mechanism Rated Closing Voltage (DC) | V | AC、DC 110, 220 | |||
| 14 | Operating Mechanism Rated Opening Voltage (DC) | V | AC、DC 110, 220 | |||
| 15 | Contact Gap | mm | 11±1 | |||
| 16 | Over-Travel (Contact Spring Compression Length) | mm | 3.5±0.5 | |||
| 17 | Three-Phase Contact Bounce Time (During Opening/Closing) | ms | ≤2 | |||
| 18 | Contact Bounce Time During Closing | ms | ≤2 | |||
| 19 | Average Opening Speed | m/s | 0.9–1.2 | |||
| Average Closing Speed | m/s | 0.5–0.8 | ||||
| 20 | Opening Time | At Maximum Operating Voltage | s | ≤0.05 | ||
| 21 | At Minimum Operating Voltage | ≤0.08 | ||||
| 22 | Closing Time | s | 0.1 | |||
| 23 | Main Circuit Resistance | μΩ | 630 ≤50 | 1250 ≤45 | ||
| 24 | Permissible Cumulative Wear Thickness of Moving/Fixed Contacts | mm | 3 | |||
Product Display
Outline and Installation Dimension
Inside the brackets: 275mm phase spacing
Ordering Instructions
Order Specifications Required from Customers:
a) Product Name: Model Number. Rated Current;
b) Rated Current. Number of Poles;
c) Minimum Order Quantity.
a) Product Name: Model Number. Rated Current;
b) Rated Current. Number of Poles;
c) Minimum Order Quantity.
Frequently Asked Questions (FAQ)
Q
What is the rated voltage of the VSB-12 High-Voltage Vacuum Circuit Breaker?
The VSB-12 has a rated voltage of 12kV and a maximum operating voltage of 12kV, making it suitable for medium-voltage distribution systems.
Q
What is the mechanical life of the VSB-12 circuit breaker?
The VSB-12 is rated for 20,000 mechanical operations, ensuring long-term reliable performance in demanding environments.
Q
What operating voltages are supported for the closing and opening mechanisms?
Both the rated closing and opening voltages support AC and DC 110V / 220V, providing flexible compatibility with different control systems.
Q
What is the rated short-circuit breaking current of the VSB-12?
The VSB-12 supports rated short-circuit breaking currents of 20/25 kA, 31.5 kA, and 40 kA depending on the configuration selected, meeting various fault interruption requirements.
Q
What is the rated operating sequence of the VSB-12?
The rated operating sequence is O – 0.3s – CO – 180s – CO, which defines the standard open-close cycle timing for safe and reliable circuit interruption.
Q
What information is required when placing an order for the VSB-12?
When ordering, customers are required to provide: product name and model number with rated current, the number of poles, and the minimum order quantity. Please contact us with these details to receive an accurate quotation.







Claire
Mr.Fu

Claire