China Suppliers Factory: Single Phase Current-Limiting Protector for Electrical Fire Safety and Fast Fault Response
Technical Parameters
| Technical Specifications | Unit | Parameters |
|---|---|---|
| Rated Current | A | 20\32\40 |
| Supply Voltage | VAC | 220 |
| Display Mode | - | Chinese LCD Screen |
| Short-Circuit Protection | us | <150 |
| Overload Protection | %In/s | Action range: 0-100%In (configurable); Delay: 0-60 |
| Temperature Monitoring | ℃/s | Action range: 0-85 (configurable); Delay: 0-60 |
| Communication Mode | - | Wired RS485; Wireless LORA, NB, 4G (optional) |
| Ambient Temperature | ℃ | -20 to 85 |
| Ambient Humidity | %RH | <95 |
| Product Size | mm | 100(L)*72(W)*70(H) |
| Installation Method | - | Standard 35mm DIN Rail Mounting |
Product Display
Outline and Installation Dimension
Basic Functions
This device provides short-circuit protection (100μs fast current-limiting + alarm), overload protection (3–60s adjustable delay + alarm), and over-temperature protection (current-limiting + alarm). It also monitors over/under-voltage, line temperature, and leakage (alarm + optional current-limiting). RS485/wireless (optional) enables remote monitoring via platforms.
Important Information
Important Notes:
- The protector uses non-mechanical contacts: when in current-limiting mode, its output still carries voltage — never touch terminals while live; always power off before inspection/maintenance.
- Overheating (from high ambient temperature or poor ventilation) will trigger protection: let it cool down before reuse; ensure good ventilation.
Other Notes:
- Leakage transformers and wire temperature sensors are optional.
- Match the protector’s rated current to the upstream breaker (e.g., 32A breaker → set protector to 32A); never use mismatched ratings.
- Install in non-corrosive, well-ventilated areas (or heat-dissipating enclosures); avoid humidity and dust.
- Follow wiring diagrams; tighten terminals to prevent poor contact or overheating.
Frequently Asked Questions
Q:
How fast does the protector react to a short circuit?
The device features an ultra-fast current-limiting response time of less than 150 microseconds (us) to effectively suppress short-circuit currents and prevent electrical fires.
Q:
Is it safe to touch the terminals when the protector is in current-limiting mode?
No, it is not safe. The protector utilizes non-mechanical contacts, which means the output terminals still carry voltage even when in current-limiting mode. Always disconnect the upstream power source before performing maintenance.
Q:
How do I properly match the protector's rated current?
You must match the protector’s rated current settings directly to the upstream circuit breaker. For example, if you are using a 32A breaker, you must set the protector to 32A. Mismatched ratings must never be used.
Q:
What communication methods are available for remote monitoring?
The protector comes standard with wired RS485 communication. Additionally, wireless communication modules such as LORA, NB-IoT, and 4G can be optionally integrated for remote platform monitoring.
Q:
What should I do if the over-temperature protection is triggered?
If protection is triggered due to high ambient temperatures or restricted airflow, allow the device to cool down completely before attempting to reuse it. Ensure the installation environment is well-ventilated.