China Suppliers Factory Miniature Single-Phase Current-Limiting Protector with LCD Screen 220VAC for Enhanced Safety
Technical Parameters
| Specifications | Unit | Parameters |
| Rated Current | A | 20 / 32 / 40 / 50 / 63 / 80 |
| Supply Voltage | VAC | 220 (175~250V) |
| Display | — | LCD Screen |
| Short Circuit Protection | ms | <150 |
| Overload Protection | — | Range: 0~100%In adjustable; Delay: 0~60s |
| Overvoltage Protection | — | Range: 221~300V adjustable; Delay: 0~60s |
| Undervoltage Protection | — | Range: 100~187V adjustable; Delay: 0~60s |
| Temperature Monitoring | — | Range: 0~85℃ adjustable; Delay: 0~60s (Optional) |
| Communication | — | Wired RS485, Wireless LORA, NB, 4G (Optional) |
| Operating Temperature | ℃ | -20~85 |
| Humidity | RH | <95% |
| Dimensions | mm | 105(L) × 56(W) × 67(H) |
| Mounting | — | Standard 35mm DIN rail |
Product Display
Outline and Installation Dimension
LCD Display Setting Parameters
| Channel | Alarm Threshold Range | Default Alarm Value | Default Protection Setting | Delay Range | Default Delay |
| Overvoltage | 221–300V | 242V | ON | 0–60s | 3s |
| Undervoltage | 100–219V | 187V | ON | 0–60s | 3s |
| Current | 0–100%In | 100%In | ON | 0–60s | 3s |
| Internal Temperature | 0–85°C | 80°C | ON | 0–60s | 3s |
| Line Temperature | 0–85°C | 80°C | ON | 0–60s | 3s |
| Leakage Current | 30–1000mA | 30mA | ON | 0–60s | 3s |
Other Considerations
- ● The leakage current transformer is an optional accessory.
- ● The line temperature sensor is an optional accessory.
- ● When selecting a current-limiting protector, the rated current set for the protector must match that of the circuit breaker immediately upstream. For example, if the upstream circuit breaker has a rated current of 32A, the current-limiting protector must also be set to 32A. To ensure proper operation, never use a current-limiting protector in a circuit where its rated current does not match that of the upstream circuit breaker.
- ● The current-limiting protector features a DIN-rail mounting design. It can be installed on a switchgear panel or inside an enclosure with excellent heat dissipation. Ensure the installation location is free of water droplets, corrosive gases, and dust, and pay attention to ambient temperature and ventilation.
- ● Follow the wiring diagram strictly during installation. To prevent excessive contact resistance from causing local overheating and to avoid malfunctions due to poor connections, ensure all terminal screws on the protector are securely tightened.
Frequently Asked Questions
Q
What rated current options are available for this current-limiting protector?
A
The current-limiting protector is available in six rated current options: 20A, 32A, 40A, 50A, 63A, and 80A, covering a wide range of residential and commercial circuit requirements.
Q
How is the current-limiting protector installed?
A
The protector uses a standard 35mm DIN rail mounting design, making it easy to install on a switchgear panel or inside an enclosure. Ensure the installation area has good ventilation and is free from moisture, corrosive gases, and dust.
Q
What communication interfaces does this protector support?
A
The protector supports wired RS485 communication as standard. Optional wireless communication modules are also available, including LORA, NB (Narrowband IoT), and 4G, enabling flexible remote monitoring and smart grid integration.
Q
What protection functions does the LCD display allow users to configure?
A
Via the LCD display, users can configure and adjust protection parameters for overvoltage (221–300V), undervoltage (100–219V), overcurrent (0–100%In), internal temperature (0–85°C), line temperature (0–85°C), and leakage current (30–1000mA). Each channel supports an independent delay setting from 0 to 60 seconds.
Q
Does the rated current of the protector need to match the upstream circuit breaker?
A
Yes. The rated current of the current-limiting protector must always match the rated current of the immediately upstream circuit breaker. For example, if the upstream breaker is rated at 32A, the protector must also be configured to 32A. Mismatched ratings can cause improper operation or safety hazards.
Q
Are the leakage current transformer and line temperature sensor included as standard?
A
No. Both the leakage current transformer and the line temperature sensor are optional accessories. They can be added based on specific application requirements to extend the protection and monitoring capabilities of the device.