China SJKM1 Moulded Case Circuit Breaker (MCCB) Factory | Reliable Power Protection from Leading Suppliers

,

The SJKM1 Moulded Case Circuit Breaker (MCCB) is expertly engineered for AC power systems operating at 50/60Hz, accommodating voltages up to 690V and currents up to 1250A. This high-performance SJKM1 MCCB provides dependable protection against overloads, short circuits, and undervoltage conditions in diverse distribution networks. Models with frame sizes reaching 400A can effectively safeguard motors, making it an essential component for industrial and commercial applications. As a reliable product from a leading China factory, the SJKM1 complies with stringent standards such as IEC 60947-2 and GB14048.2, ensuring safe power distribution and optimal equipment protection. Its robust construction also supports infrequent switching and efficient motor starting. Choose our SJKM1 MCCB for reliable protection sourced from trusted suppliers in China.

,

    Type Designation
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-5
    Manufacturer Code
    Molded Case Circuit Breaker Code
    Design Code
    Frame Size
    Short-Circuit Breaking Capacity Level 4
    Operation method 3
    Number of Poles 2
    Trip Unit Method & File Code
    Function Code 1
    Type code (See Table 1 for N-pole of four-pole, no code for three-pole)

    Notes:

    1. There is no code for distribution circuit breakers; for motor-protection circuit breakers, use 2 to represent.

    2. Number of poles: 2 for two-pole; 3 for three-pole; 4 for four-pole.

    3. For handle-direct operation: use D to represent for power-distribution use, and use Z to represent for conversion-locking use.

    4. For economy type: represent with E; for standard type: represent with M; for higher-reliability type: represent with H; for high-breaking type: represent with L.

    Product Display
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-(1)
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-(2)
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-(3)
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB)-(4)
    N-pole Type Code
    Type Code Description
    Type A No over-current release element is installed on the N-pole, and the N-pole is always connected, and does not close and open together with the other three poles.
    Type B No over-current release element is installed on the N-pole, and the N-pole closes and opens together with the other three poles (the N-pole closes first and opens later).
    Type C An over-current release element is installed on the N-pole, and the N-pole closes and opens together with the other three poles (the N-pole closes first and opens later).
    Type D An over-current release element is installed on the N-pole, and the N-pole is always connected, and does not close and open together with the other three poles.
    Release Modes and Accessory Codes
    Accessory Name Without Accessory Alarm Contact Shunt Release Auxiliary Contact Under-voltage Release Shunt Release Auxiliary Contact Two-group Auxiliary Contacts Shunt Release Under-voltage Release Auxiliary Contact Under-voltage Release
    Release Mode Instantaneous Code 200 208 210 220 230 240 250 260 270
    Release Mode Compound Code 300 208 310 320 330 340 350 360 370

    (Continued from the previous table)

    Accessory Name Shunt Release Alarm Contact Auxiliary Contact Alarm Contact Under-voltage Release Alarm Contact Shunt Release Auxiliary Contact Alarm Contact Two-group Auxiliary Contact Alarm Contact Auxiliary Contact Under-voltage Release Alarm Contact
    Release Mode Instantaneous Code 218 228 238 248 268 278
    Release Mode Compound Code 318 328 338 348 268 378

    Notes:

    1) 200 indicates the circuit breaker body with only an electromagnetic release; 300 indicates the circuit breaker body with thermal and electromagnetic releases.

    2) For the two-level products SJKM1-125 and SJKM1-250, only 210, 310, 220, 320, 230, and 330 are available.

    Normal Operating Conditions and Installation Conditions

    Ambient temperature: The circuit breaker can operate normally at an ambient temperature range of -5°C to +40°C (except for special orders).

    Altitude: The altitude of the installation site of the circuit breaker shall not exceed 2000m.

    Pollution degree: The pollution degree of the circuit breaker is Grade 3.

    Installation category: The installation category of the circuit breaker is Category III.

    Installation position: The circuit breaker can be installed horizontally, vertically, or flat, without reducing its electrical performance.

    Main Parameters and Technical Performances
    Circuit Breaker Model SJKM1-63 SJKM1-125 SJKM1-250 SJKM1-400 SJKM1-630 SJKM1-800 SJKM1-1250
    Pole Number 3 4 3 2 4 3 2 4 3 4 3 4 3 4 3 4
    Rated Current In A 10 16 20 25 32 40 50 63 16 20 25 32 40 50 63 80 100 125 100 125 140 160 180 200 225 250 225 250 315 350 400 400 500 630 630 700 800 800 1000 1250
    Rated Insulation Voltage Ui (V) 690 1000 1000 1000 1000 1000 1000
    Rated Impulse Withstand Voltage Uimp V 6000 8000
    Rated Working Voltage Ue V 400 AC400/690 AC400/690 AC400/690 AC400/690 AC400/690 AC400/690
    Breaking Capacity Level L M L M H L M H L M H L M H H H
    Ultimate Short-Circuit Breaking Capacity Icu (kA) (0-tCO) 400V 25 50 35 50 85 35 50 85 50 65 100 50 65 100 100 100
    690V 25 25 30 30 25
    Service Short-Circuit Breaking Capacity Ics (kA) (0-tCOtCO) 400V 18 30 25 35 50 25 35 65 35 50 65 35 50 65 65 50
    690V 15 15 20 20 20
    Appearance and Installation Dimensions

    Appearance and installation dimensions of the fixed-type front-connected and rear-connected wiring

    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (1)
    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (2)

    Appearance and installation dimensions of fixed-type front and rear wiring

    Model Number Overall Dimensions (mm) Mounting Dimensions (mm) Dimensions for Rear Terminal Wiring (mm)
    L L1 W H H1 H2 a b φd a1 b1 d1 H3 H4
    SJKM1-63L 3 135 21 76 88 72 19 25 117 4 25 117 18 52 75
    SJKM1-63M 97 82 28
    SJKM1-63 4 103
    SJKM1-125L 150 51 92 86 68 24 30 129 4.5 30 132 22 65 100
    SJKM1-125M 3 104 86 23
    SJKM1-125H
    SJKM1-125 2 65 ---
    4 122 30
    SJKM1-250L 165 64 107 108 87 25 35 126 5.5 35 144 24 70 110
    SJKM1-250M 3 165 107 124.5 104 24.5
    SJKM1-250H
    SJKM1-250 2 75 --
    4 142
    SJKM1-400 3 257 105 149 150 100 36.5 44 195 6.5 44 225 32 70 120
    4 198
    SJKM1-630 3 270 118 182 155 108 41 58 200 7 58 234 40 70 120
    4 240
    SJKM1-800 3 282 102 210 158 103 34.5 70 243 7 70 243 48 70 125
    4 280
    SJKM1-1250 3 406 104 210 190 140.5 58.5 70 375 10 - - -
    手柄 H W Protrusion in the middle L W H
    63 17 13.5 63 44 22 5.5
    125 19 13 125 51 23 5.5
    250 22 12.5 250 52 23 4
    400 43.5 33.5 400 89.5 65 7
    630 44 33.5 630 90 65.5 7
    800 40 33.5 800 105 61 5
    1250 51 41 1250 100 78 16

    Appearance and installation dimensions of the plug-in type front-connected wiring

    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (3)

    Appearance and installation dimensions of plug-in type rear-panel wiring

    Model W L A H1 G G1 a b d
    SJKM1-63 75 135 18 28 17 15 50 60 6
    SJKM1-125 92 170 38 50 33 28 60 56 6.5
    SJKM1-250 107 186 46 50 33 40 70 54 7
    SJKM1-400 144 280 50 60 40 48 88 143 9
    SJKM1-630 182 300 65 60 40 53 100 123 9
    SJKM1-800 212 298 57 100 43 129 140 143 9

    Outline and Installation Schematic Diagram of Withdrawable Device

    SJKM1-Moulded-Case-Circuit-Breaker-(MCCB) (4)

    Outline and Installation Dimensions of Withdrawable Device

    Model Pole Overall Dimensions Installation Dimensions
    L1 L2 L3 H1 H2 H3 W1 W2 φd1 A B φd2
    SJKM1-400/M 3P 310 339 203 253 17.5 77 48 223 φ11 96 134 φ6.5
    4P 310 339 203 253 17.5 77 48 271 φ11 144 134 φ6.5
    SJKM1-630/M 3P 341 381 211 282 17.5 92 58 253 φ13 116 140 φ6.5
    4P 341 381 211 282 17.5 92 58 311 φ13 174 140 φ6.5
    SJKM1-800/M 3P 367 410 241 238 26 73 70 289 φ13 140 131 φ6.5
    4P 367 410 241 238 26 73 70 359 φ13 210 131 φ6.5
    Frequently Asked Questions (FAQ)
    What does the type designation code of the SJKM1 Molded Case Circuit Breaker represent?
    The type designation code of the SJKM1 MCCB includes information about the manufacturer code, molded case circuit breaker code, design code, frame size, short-circuit breaking capacity level, operation method, number of poles, trip unit method & file code, function code, and N-pole type code. Each position in the code corresponds to a specific parameter of the product.
    What are the differences between the N-pole types (A, B, C, D) in the SJKM1 MCCB?
    Types A and B have no over-current release element on the N-pole. Type A keeps the N-pole always connected (independent of other poles), while Type B operates the N-pole together with the other three poles (closing first, opening last). Types C and D have an over-current release element on the N-pole. Type C operates with the other poles (closing first, opening last), while Type D keeps the N-pole always connected.
    What are the normal operating and installation conditions for the SJKM1 MCCB?
    The SJKM1 MCCB operates normally at ambient temperatures from -5°C to +40°C, at altitudes not exceeding 2000m, with a pollution degree of Grade 3 and installation category of Category III. It can be installed horizontally, vertically, or flat without any reduction in electrical performance.
    What breaking capacity levels are available for the SJKM1 MCCB series, and what do they mean?
    The SJKM1 MCCB series offers four breaking capacity levels: E (Economy type), M (Standard type), H (Higher-reliability type), and L (High-breaking type). These codes indicate the short-circuit breaking capability and design reliability of the circuit breaker, with higher levels offering increased breaking capacity values (Icu/Ics) at rated voltages.
    What accessories are available for the SJKM1 MCCB, and how are they coded?
    The SJKM1 MCCB supports a variety of accessories including alarm contacts, shunt releases, auxiliary contacts, under-voltage releases, and combinations thereof. Each configuration is assigned a specific numeric code (e.g., 200 for no accessory, 210 for shunt release only, 220 for auxiliary contact, etc.). Both instantaneous and compound release modes have separate code tables.
    What frame sizes and rated current ranges are available in the SJKM1 MCCB series?
    The SJKM1 MCCB series covers a wide range of frame sizes from SJKM1-63 up to SJKM1-1250. Rated current ranges vary by frame: SJKM1-63 covers 10A–63A, SJKM1-125 covers 16A–125A, SJKM1-250 covers 100A–250A, SJKM1-400 covers 225A–400A, SJKM1-630 covers 400A–630A, SJKM1-800 covers 630A–800A, and SJKM1-1250 covers 800A–1250A, available in 2-pole, 3-pole, and 4-pole configurations.