China MS116 Low Voltage Motor Protection Circuit Breaker 16A - Factory Direct Suppliers for Reliable Motor Control

,

The ABB MS116-16 is an efficient and compact motor protection circuit breaker, ideal for reliable motor control and protection in various industrial applications. This product offers extensive protection against overloads, short circuits, and phase loss for three-phase motors with a capacity of up to 7.5kW at 400V. With an adjustable current range of 16A and a Class 10A tripping characteristic, it guarantees safe motor starting while minimizing the risk of nuisance tripping. The unit is designed with a robust 50kA breaking capacity at 400V and features temperature compensation ranging from -25°C to +60°C. Additionally, it comes equipped with a lockable handle for enhanced safety isolation. Its compact 45mm width efficiently saves panel space, and the modular design enables seamless integration with contactors and auxiliary contacts. As a trusted product from a leading China supplier, the ABB MS116-16 exemplifies superior manufacturing and quality standards, making it an excellent choice for factories seeking reliable motor protection solutions.

,

    Type and Meaning
    MS116-6.png
    1 Series Number
    MS: Thermal-magnetic trip
    MO: Magnetic-only trip
    2 Rated current, trip class and breaking capacity
    116-32A, Class 10A (10/16/30/50kA)
    132-32A, Class 10A (25/50/100kA)
    450-50A, Class 10A (50kA)
    451-50A, Class 20A (50kA)
    495-100A, Class 10A (50kA)
    496-100A, Class 20A (100kA)
    497-100A, Class 10A (100kA)
    3 Thermal protection setting value
    Product Features
    Model MS116
    Thermal protection and electromagnetic protection Yes
    Electromagnetic protection -
    Phase failure protection Yes
    Switch position ON/OFF
    Magnetic release indication -
    Lockable handle, no accessories required -
    Isolation function Yes
    Width 45mm
    Rated operating current 0.16...32A
    Current setting range 0.1...32A
    Ambient air temperature -25...+55°C*)
    Product Display
    MS116 Low Voltage Motor Protection Circuit Breaker top
    MS116 LV Motor Protection Circuit Breaker view
    Technical Parameters
    Type MS116 MS132 MS165
    Thermal and magnetic protection Yes Yes Yes
    Magnetic protection - - -
    Phase failure protection Yes Yes Yes
    Switch position ON/OFF ON/OFF/TRIP ON/OFF/TRIP
    Magnetic trip indication - Yes Yes
    Lockable handle, no accessories required - Yes Yes
    Isolation function Yes Yes Yes
    Width 45mm 45 mm 55 mm
    Rated operational current (Iₑ) 0.16...32A 0.16..32A 16...65 A
    Current setting range 0.1...32 A 0.1...32 A 10...65A
    Ambient air temperature -25...+55C -25...+60C" -20…+60*C"
    "Compensated
    Rated Short-Circuit Breaking Capacity (for 400/415V)
    Motor Rated Power Thermal Trip Setting Range Type Short-Circuit Breaking Capacity
    Icu Ics
    0.03 kW 0.1…0.16A MS116-0.16 50 kA 50 kA
    0.06 kW 0.16…0.25A MS116-0.25 50kA 50 kA
    0.09 kW 0.25…0.4A MS116-0.4 50kA 50 kA
    0.18 kW 0.4…0.63A MS116-0.63 50kA 50kA
    0.25 kW 0.63…1.0A MS116-1.0 50kA 50kA
    0.55 kW 1.0…1.6A MS116-1.6 50 kA 50 kA
    0.75kW 1.6…2.5A MS116-2.5 50 kA 50 kA
    1.5kW 2.5…4.0A MS116-4.0 50kA 50kA
    2.2 kW 4.0…6.3A MS116-6.3 50kA 50kA
    4.0 kW 6.3...10 A MS116-10 50 kA 50 kA
    5.5 kW 8…12A MS116-12 25 kA 25 kA
    7.5 kW 10…16A MS116-16 16kA 16kA
    7.5 kW 14...20 A
    7.5kW 16…20 A MS116-20 15kA 10 kA
    11 kW 18…25A
    11 kW 20…25A MS116-25 15kA 10 kA
    15 kW 25…32A MS116-32 10 kA 10 kA
    15kW 23...32A
    22 kW 30…42A
    22kW 40...54 A
    30 kW 52…65A
    1) 690V
    Outline and Installation Dimension
    MS116-5
    Product Dimensions (mm), inches
    Frequently Asked Questions (FAQ)
    Q1: What is the difference between MS116 (thermal-magnetic trip) and MO series (magnetic-only trip)?
    The MS116 uses thermal-magnetic trip technology, which provides both overload protection (thermal) and short-circuit protection (magnetic). The MO series provides magnetic-only trip, which is suitable for applications where overload protection is handled by a separate device, such as a soft starter or variable frequency drive.
    Q2: What is the rated current range of the MS116 motor protection circuit breaker?
    The MS116 has a rated operating current range of 0.16 A to 32 A, with a current setting range of 0.1 A to 32 A. This makes it suitable for protecting motors from 0.03 kW up to 15 kW at 400/415V.
    Q3: Does the MS116 provide phase failure protection?
    Yes, the MS116 includes built-in phase failure protection. This feature detects loss of one phase in a three-phase system and trips the breaker to prevent motor damage from running in a single-phase condition.
    Q4: What is the short-circuit breaking capacity (Icu) of the MS116 at 400/415V?
    The short-circuit breaking capacity varies by model. For example, MS116-0.16 to MS116-10 offer up to 50 kA, MS116-12 offers 25 kA, MS116-16 offers 16 kA, and MS116-20 and MS116-25 offer 15 kA (Icu). The MS116-32 has a breaking capacity of 10 kA.
    Q5: What is the ambient operating temperature range for the MS116?
    The MS116 is designed to operate in ambient air temperatures ranging from -25°C to +55°C (compensated). Compared to the MS132 and MS165 which can operate up to +60°C, the MS116 is slightly more limited but still covers most standard industrial environments.
    Q6: How does the MS116 compare to the MS132 and MS165 in terms of features?
    All three models offer thermal and magnetic protection, phase failure protection, and isolation function. However, the MS132 and MS165 additionally provide ON/OFF/TRIP switch positions, magnetic trip indication, and a lockable handle without accessories — features not available on the MS116. The MS165 also has a wider body (55mm vs 45mm) and supports higher currents up to 65A.