China Current-limiting Protector System Main Unit - Reliable Suppliers and Factory Solutions for Power Data Management
Functions
- ✔ Digital processing technology for real-time monitoring and display of each distribution circuit's working status
- ✔ RS485 communication technology for real-time and accurate transmission of operating parameters and control commands
- ✔ Multi-level distributed intelligent control system for zone protection of distribution circuits
- ✔ Dangerous electricity warning and alarm, high-risk current cutoff
- ✔ Intelligent data analysis and intelligent parameter setting
- ✔ Backup power system capable of supporting system operation for more than 12 hours
- ✔ System self-check and network inspection functions
- ✔ Audible and visual alarm, remote switching functions
- ✔ Alarm and fault record storage, query, and printing functions
Product Display
Technical Parameters
| Technical Specification | Details |
|---|---|
| Operating Power Supply | AC220V |
| Display | 6-inch LCD Screen |
| Monitoring Points | Standard 128 points; customizable 256, 384, 512 points |
| Alarm Method | Audible and visual alarm, alarm sound ≥70dB |
| Storage Records | ≥10,000 records |
| Printer | Micro thermal printer |
| Backup Power | UPS power supply |
| Communication Method | RS485 |
| Communication Cable | ZR-RVVP-2×1.0mm² shielded twisted pair |
| Communication Distance | ≤500m |
| Ambient Temperature | -20℃ ~ 60℃ |
| Altitude | ≤4500 meters |
| Product Dimensions | 550×400×130mm |
| Installation Method | Wall-mounted installation |
Main Components
-
1Central Processing Unit (CPU): Functions as the "brain" of the system host, responsible for processing and analyzing all data received from field protectors, and making judgments and responses based on preset logic.
-
2Communication Unit: Responsible for data exchange with on-site current-limiting protectors. Common communication methods include RS485 bus, following protocols such as Modbus-RTU.
-
3Display Unit: Used to intuitively display system operation status, real-time data, alarm information, and historical records, facilitating viewing and operation by management personnel.
-
4Alarm Unit: When abnormalities are detected, it issues alerts through audible and visual means to draw management personnel's attention.
Frequently Asked Questions
Q What is the maximum number of monitoring points supported by the current-limiting protector system?
The standard configuration supports 128 monitoring points. The system is customizable and can be expanded to 256, 384, or 512 monitoring points to meet the needs of larger installations.
Q How long can the backup power system keep the system running during a power outage?
The built-in UPS backup power system is capable of supporting continuous system operation for more than 12 hours, ensuring uninterrupted monitoring and protection even during power failures.
Q What communication method does the system use, and what is the maximum communication distance?
The system uses RS485 communication technology with ZR-RVVP-2×1.0mm² shielded twisted pair cable. The maximum communication distance is ≤500 meters, ensuring reliable data transmission across large facility areas.
Q What types of alarms does the system support?
The system supports both audible and visual alarms. The alarm sound level is ≥70dB. In addition, it offers remote switching functions, so management personnel can be notified and respond promptly regardless of their location.
Q How many alarm and fault records can the system store?
The system can store a minimum of 10,000 alarm and fault records. These records can be queried and printed via the built-in micro thermal printer for audit and maintenance purposes.
Q What are the environmental conditions and installation requirements for this system?
The system operates in ambient temperatures ranging from -20℃ to 60℃ and at altitudes of up to 4,500 meters. It is installed using a wall-mounted method with product dimensions of 550×400×130mm, making it suitable for a wide range of indoor environments.







Claire
Mr.Fu

Claire