China CJX1 (3TF) Series AC Contactors 9-400A 690V - Reliable Suppliers and Factory for Industrial Automation Solutions
Features
- 1For better safety, conductive parts are enclosed.
- 2Small size, light weight; material of arc chute adopts unsaturated resin, with good arc resistance and no splitting.
- 3The arc chute is enclosed, arc-over distance is small, supporting a compact electric cabinet.
- 4Construction of main contacts system is unique, abrasion of the contacts is small, with long electric endurance.
- 5The operation of the magnet has many advantages such as good reliability, little consumption, low noise and high mechanical strength.
- 6The contactors have higher operation frequency and control capacity.
- 7Auxiliary contact block may be attached to CJX1-F(3TF30-50) series AC contactors.
- 8SIGUT–Siemens patent terminal ensures easy and reliable connection, strong shock resistance and perfect safety protection.
Main Technical Specifications
| Type | CJX1-9F 3TF30 |
CJX1-9F 3TF40 |
CJX1-12F 3TF31 |
CJX1-12F 3TF41 |
CJX1-16F 3TF32 |
CJX1-16F 3TF42 |
CJX1-22F 3TF33 |
CJX1-22F 3TF43 |
CJX1-32F 3TF34 |
CJX1-32 3TF44 |
CJX1-38F 3TF35 |
CJX1-38 3TF45 |
CJX1-45 3TF46 |
CJX1-63 3TF47 |
CJX1-75 3TF48 |
CJX1-75 3TF49 |
CJX1-110 3TF50 |
CJX1-140 3TF51 |
CJX1-170 3TF52 |
CJX1-205 3TF53 |
CJX1-250 3TF54 |
CJX1-300 3TF55 |
CJX1-400 3TF56 |
|||
| Rated insulation voltage (V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |||
| Rated operational current (380V) (A) | AC-3 | 9 | 9 | 12 | 12 | 16 | 16 | 22 | 22 | 32 | 32 | 38 | 38 | 45 | 63 | 75 | 85 | 110 | 140 | 170 | 205 | 250 | 300 | 400 | ||
| AC-4 | 3.3 | 3.3 | 4.3 | 4.3 | 7.7 | 7.7 | 8.5 | 8.5 | 15.6 | 15.6 | 18.5 | 18.5 | 24 | 28 | 34 | 42 | 54 | 68 | 75 | 96 | 110 | 125 | 150 | |||
| Rated outputs of three-phase motors at 50Hz (KW) | AC-3 | 230/220V 400/380V 500V 690/660V 1000V |
2.4 4 5.5 5.4 - |
2.4 4 5.5 5.5 - |
3.3 5.5 7.5 7.5 - |
3.3 5.5 7.5 7.5 - |
4 7.5 9 11 - |
4 7.5 9 12 - |
5.5 11 11 11 - |
5.5 11 11 11 - |
8.5 15 21 23 - |
8.5 15 21 23 - |
11 18.5 25 23 - |
11 18.5 25 23 - |
15 22 30 39 - |
18.5 30 41 55 - |
22 37 50 67 39 |
26 45 59 67 39 |
37 55 76 100 65 |
43 75 98 100 65 |
55 90 118 156 90 |
64 110 145 156 90 |
78 132 178 235 132 |
93 160 210 235 132 |
125 200 284 375 250 |
|
| AC-4 | 400/380V 690/660V |
1.48/1.4 2.54/2.4 |
1.48/1.4 2.54/2.4 |
2/1.9 3.45/3.3 |
2/1.9 3.45/3.3 |
3.5 6 |
3.5 6 |
4 6.6 |
4 6.6 |
7.5 13 |
7.5 13 |
9 15.5 |
9 15.5 |
12.6/12 21.8/20.8 |
14.7/14 25.4/24.3 |
17.9/17 30.9/29.5 |
22/21 38/36 |
28.4/27 49/46.9 |
36/35 63/60 |
40/38 69/66 |
52/50 90/86 |
61/58 105/100 |
69/66 119/114 |
85/81 147/140 |
||
| Mechanical endurance (×10⁶) | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |||
| Electrical endurance (×10⁶) | AC-3 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | ||
| AC-4 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | |||
| Switching frequency (1/h) | AC-3 | 1000 | 1000 | 1000 | 1000 | 750 | 750 | 750 | 750 | 750 | 750 | 600 | 600 | 1200 | 1000 | 1000 | 850 | 1000 | 750 | 700 | 500 | 700 | 500 | 500 | ||
| AC-4 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 200 | 200 | 400 | 300 | 300 | 200 | 300 | 200 | 200 | 130 | 200 | 130 | 150 | |||
| Coil voltage tolerance | (0.8~1.1)Us | |||||||||||||||||||||||||
| Power consumption of coil (50Hz) (AC) | Closed (VA) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 12.1 | 12.1 | 12.1 | 12.1 | 17 | 17 | 32 | 32 | 39 | 39 | 58 | 58 | 84 | 84 | 115 | ||
| Power Factor (p.f.) | 0.29 | 0.29 | 0.29 | 0.29 | 0.29 | 0.29 | 0.29 | 0.29 | 0.28 | 0.28 | 0.28 | 0.28 | 0.29 | 0.29 | 0.29 | 0.29 | 0.24 | 0.24 | 0.26 | 0.26 | 0.24 | 0.24 | 0.33 | |||
| Closing (VA) | 68 | 68 | 68 | 68 | 68 | 68 | 68 | 68 | 101 | 101 | 101 | 101 | 183 | 183 | 330 | 330 | 550 | 550 | 910 | 910 | 1430 | 1430 | 2450 | |||
| Power Factor (p.f.) | 0.82 | 0.82 | 0.82 | 0.82 | 0.82 | 0.82 | 0.82 | 0.82 | 0.83 | 0.83 | 0.83 | 0.83 | 0.6 | 0.6 | 0.6 | 0.6 | 0.45 | 0.45 | 0.38 | 0.38 | 0.34 | 0.34 | 0.21 | |||
| Convention althermal current (A) | 20 | 20 | 20 | 20 | 30 | 30 | 30 | 30 | 55 | 55 | 55 | 55 | 80 | 90 | 100 | 100 | 160 | 160 | 210 | 220 | 300 | 300 | 400 | |||
| Conventional thermal current of auxiliary contacts (A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |||
| Rated operational current of auxiliary contacts (A) | AC-15 380/220V | 4-6 | 6-10 | 4-6 | 6-10 | 4-6 | 6-10 | 4-6 | 6-10 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | 4-6 | ||
| Weight (kg) | AC0.37 | AC0.43 | AC0.37 | AC0.43 | AC0.45 | AC0.49 | AC0.45 | AC0.49 | AC0.68 | AC0.8 | AC0.68 | AC0.8 | AC1.4/1.6 | AC1.4/1.6 | AC2.3/2.5 | AC2.3/2.5 | AC3.3/3.5 | AC3.3/3.5 | AC4.8/5.0 | AC4.8/5.0 | AC6.2/6.4 | AC6.2/6.4 | AC8.5/8.7 | |||
Product Display
Outline and Installation Dimension

| CJX1(3TF30~38 、40~45) AC Contactor | ||||||||||||||||||||
| Type | amax | b | cmax | d | emax | f | Φ | |||||||||||||
| CJX1F-9/22 | 79 | 60±0.60 | 46 | 35±0.50 | 106 | 8 | 4.8 | |||||||||||||
| CJX1F-12/22 | 79 | 60±0.60 | 46 | 35±0.50 | 106 | 8 | 4.8 | |||||||||||||
| CJX1F-16/22 | 89 | 75±0.60 | 46 | 35±0.50 | 116 | 8 | 4.8 | |||||||||||||
| CJX1F-22/22 | 89 | 75±0.60 | 46 | 35±0.50 | 116 | 8 | 4.8 | |||||||||||||
| CJX1F-32/22 | 105 | 75±0.60 | 82 | 35±0.50 | 112 | 8 | 5.0 | |||||||||||||
| CJX1F-38/22 | 105 | 75±0.60 | 82 | 35±0.50 | 112 | 8 | 5.0 | |||||||||||||
| CJX1(3TF46~51) AC Contactor | ||||||||||||||||||||
| Type | amax | b | cmax | d | emax | f | Φ | |||||||||||||
| CJX1-45/22 | 120 | 100±0.70 | 92 | 70±0.60 | 125 | 12 | 5 | |||||||||||||
| CJX1-63/22 | 120 | 100±0.70 | 92 | 70±0.60 | 125 | 12 | 5.5 | |||||||||||||
| CJX1-75/22 | 135 | 110±0.70 | 105 | 80±0.60 | 145 | 12 | 5.5 | |||||||||||||
| CJX1-85/22 | 135 | 110±0.70 | 105 | 80±0.60 | 145 | 12 | 6.5 | |||||||||||||
| CJX1-110/22 | 158 | 130±0.80 | 125 | 100±0.70 | 155 | 12 | 6.5 | |||||||||||||
| CJX1-140/22 | 158 | 130±0.80 | 125 | 100±0.70 | 155 | 12 | 6.5 | |||||||||||||
| CJX1(3TF52~56) AC Contactor | ||||||||||||||||||||
| Type | a1 | a2 | a3 | b1 | b2 | c1 | M | e1 | f1 | g | d1 | d2 | Φg1 | |||||||
| CJX1-170 | 135 | 158 | 110 | 180 | 160 | 185 | 8 | 154 | 115 | 48 | 20 | 42 | 7 | |||||||
| CJX1-205 | 135 | 158 | 110 | 180 | 160 | 185 | 10 | 159 | 115 | 48 | 25 | 48 | 7 | |||||||
| CJX1-250 | 145 | 168 | 168 | 200 | 180 | 198 | 10 | 168 | 132 | 58 | 25 | 48 | 9 | |||||||
| CJX1-300 | 145 | 168 | 120 | 200 | 180 | 198 | 10 | 168 | 132 | 58 | 25 | 48 | 9 | |||||||
| CJX1-400 | 160 | 183 | 130 | 200 | 180 | 222 | 10 | 178 | 150 | 65 | 25 | 48 | 9 | |||||||
| CJX1-475 | 160 | 183 | 130 | 200 | 180 | 222 | 10 | 182 | 150 | 65 | 30 | 52 | 9 | |||||||
Frequently Asked Questions
QWhat is the rated insulation voltage of CJX1 / 3TF series AC contactors?
The rated insulation voltage varies by model. For smaller models (CJX1-9F to CJX1-38, 3TF30–3TF45), the rated insulation voltage is 690V. For larger models (CJX1-45 and above, 3TF46–3TF56), the rated insulation voltage is 1000V, making them suitable for a wider range of industrial power systems.
QWhat is the difference between AC-3 and AC-4 rated operational current for these contactors?
AC-3 refers to the rated current for normal motor starting and switching off during running (squirrel-cage motors), while AC-4 applies to plugging, inching, and reversing duties which involve higher breaking currents. For example, the CJX1-9F (3TF30) has an AC-3 current of 9A but only 3.3A under AC-4 conditions at 380V.
QCan auxiliary contact blocks be added to the CJX1-F series AC contactors?
Yes. Auxiliary contact blocks may be attached to CJX1-F (3TF30–50) series AC contactors. The conventional thermal current for auxiliary contacts is 10A across all models, and the rated operational current for auxiliary contacts (AC-15, 380/220V) is 4–6A or 6–10A depending on the specific model variant.
QWhat coil voltage tolerance is acceptable for CJX1 / 3TF series contactors?
The coil voltage tolerance for all models in the CJX1 / 3TF series is (0.8~1.1)Us, meaning the coil will operate reliably within 80% to 110% of the rated supply voltage. This ensures stable performance even with minor voltage fluctuations in the power supply.
QWhat is the mechanical endurance life of CJX1 / 3TF series contactors?
The mechanical endurance is 15×10⁶ operations for smaller models (CJX1-9F to CJX1-22F, 3TF30–3TF43), and 10×10⁶ operations for larger models (CJX1-32 and above). The electrical endurance under AC-3 duty is 1.2×10⁶ operations, and 0.2×10⁶ operations under AC-4 duty for all models.
QWhat are the key structural advantages of the CJX1 / 3TF series AC contactors?
The CJX1 / 3TF series features an enclosed arc chute made of unsaturated resin for excellent arc resistance, a compact design with small arc-over distance suitable for compact electric cabinets, a unique main contacts system for minimal abrasion and long electrical endurance, and SIGUT (Siemens patent) terminals for easy, reliable, and shock-resistant wiring connections.







Claire
Mr.Fu

Claire