A9~300 Series AC Contactors 50/60Hz 380V - Reliable China Suppliers & Factory for High Performance

,

The A9~300 Series AC Contactors, manufactured in China, are designed to operate effectively in 50/60Hz systems. These contactors support high voltages up to 660V and can handle operational currents up to 300A at 380V under the AC-3 category. They are perfect for long-distance circuit making and breaking, and can easily be paired with thermal overload relays or electronic starters for optimal overload protection. Key features include a robust direct-action double-break contact structure, an arc-resistant plastic housing, and durable silver alloy contacts. Additionally, the compact E-shaped iron core and flexible coil wiring options ensure easy installation. As a trusted option from reliable suppliers, these contactors are a top choice for industrial applications and are produced in our state-of-the-art factory.

,

    Type & Meaning

    CJX2-D-4
    1 AC contact
    2 Design code
    3 The basic specification code corresponds to the rated working voltage under AC-3 utilization category; and is expressed by the numerical value of the rated operating current at 380V under AC-3 application category.
    4 The main contact pairs are indicated with two figures; the ones place represents NC (normally closed) contact pairs; The tens digit represents NO (normally open) contact pairs;
    5 The auxiliary contact pairs are indicated with two figures; the ones place represents NC (normally closed) contact pairs; For contact pairs, the tens digit represents NO (normally open) contact pairs;

    Main Structure and Working Principle

    • The contactor features a positive-mounted, direct-action double-break contact structure. Its cover and body are made of arc-resistant plastic. Models A9–16 use natural arc extinguishing, while models A9–26 to 110 incorporate U-shaped arc extinguishing plates within the body to form a sealed arc chamber, delivering excellent arc extinguishing performance with zero arc-over distance. Contacts are made of anti-welding, wear-resistant silver-based alloy, offering good conductivity, long service life, and environmental friendliness. The iron core adopts an E-shaped design for compact size. Two coil wiring options are available: both terminals at one end, or one terminal at each end, ensuring flexible and convenient wiring.
    • The base is constructed from glass fiber reinforced plastic, providing high strength and good dielectric properties. Installation can be via screws or DIN rail, enabling quick and easy assembly/disassembly. Live conductive parts are fully enclosed, ensuring high safety performance.
    • The working principle of the contactor: When the control power to the contactor's pull-in coil is applied (or removed), the magnetic system generates (or dissipates) electromagnetic force, driving the moving parts to make (or break) the circuit, thus achieving the control objective.

    Product Display

    cjx2-d-ac-contactor-right-view
    cjx2-d-ac-contactor-top-view

    Technical Parameters

    • a. The installation site elevation shall not exceed 2000 m;
    • b. Ambient air temperature shall not exceed +40°C, nor shall it exceed +35°C within 24 hours. The lower limit of ambient air temperature is -5°C;
    • c. The relative air humidity at the installation site shall not exceed 50% at a maximum temperature of +40°C. Higher relative humidity is permitted at lower temperatures, e.g., 90% at 20°C. Measures must be taken to prevent dew condensation on the product due to temperature changes;
    • d. The installation site pollution class is 3;
    • e. The contactor can be mounted vertically or horizontally. If mounted vertically, the gradient between the mounting surface and the vertical plane shall not exceed ±30°; (See Fig. 1)
    CJX2-D-4

    1. The allowable application category of main circuit and the auxiliary circuit of the contactor in the table 1
    Table 1 — Application category of main circuit and the auxiliary circuit of the contactor

    Circuit Application Category Code Example of Typical Usage
    Main Circuit AC-1 Noninductive or the micro inductive load, resistance furnace
    AC-2 The starting and breaking of wire winding type asynchronous motor
    AC-3 The starting and breaking during operation of cage asynchronous motor
    AC-4 The starting, plug breaking or reverse revolution, spot moving of cage asynchronous motor
    Auxiliary Circuit AC-15 Control AC electromagnet load (>72VA)
    DC-13 Control DC magnet load

    2. Contactor rated insulation voltage (Ui), rated working voltage (Ue), conventional free air heating current (Ith), rated operating current (Ie) and rated insulation class

    Type Frame Code Rated Insulation Voltage Ui (V) Conventional Free Air Heat Current Ith (A) AC-3 Rated Operating Current Ie (A) AC-3 Control Max. Power of Generator (kW)
    220V 380V 660V 220V 380V 660V
    A9-9 16 1000 26 9 9 7 2.2 4 5.5
    A9-12 28 12 12 9 3 5.5 6.5
    A9-16 30 17 17 10 4 7.5 9
    A9-26 26 45 26 26 17 6.5 11 15
    A9-30 40 65 32 32 21 9 15 18.5
    A9-40 65 37 37 25 11 8.5 22
    A9-50 75 100 50 50 35 15 22 30
    A9-63 125 65 65 43 18.5 30 37
    A9-75 125 75 75 46 22 37 40
    A9-95 110 145 96 96 65 25 45 55
    A9-110 160 110 110 82 30 55 75
    A9-145 185 250 145 145 120 40 75 100
    A9-185 275 185 185 170 50 90 120
    A9-210 300 350 210 210 210 60 110 150
    A9-260 400 260 260 260 78 140 190
    A9-300 450 300 300 280 88 160 220

    Outline and Installation Dimension

    CJX2-D-4 Outline Dimension
    CJX2-D-4 Installation Dimension
    Type A A′ B C C′ a b1 b2 Φ Mounting Mode
    A9-9, 12, 16 44 12.5 74 74 102 35 60 50 4.5 Screw installation or TH75 mounting rail installation
    A9-26 54 12.5 90 93.5 120.5 45 80 70 4.2
    A9-30, 40 54 12.5 90 108.5 135.2 45 80 70 4.2
    A9-50, 63, 75 70 12.5 110 108 135 60 100 90 6.2 Installation or TH35 or TH75 mounting rail installation
    A9-95, 110 90 12.5 148.5 123.5 151 78 136 126 6.2 Screw installation or TH75 mounting rail installation
    A9-145, 185 Note: Refer to drawing 6 for dimension
    A9-210, 260, 300 Note: Refer to drawing 7 for dimension
    Frequently Asked Questions
    Q What is the maximum rated operating current of the A9-300 series AC contactor?
    The A9-300 model has a conventional free air heating current (Ith) of 450A, with an AC-3 rated operating current of 300A at both 220V and 380V, and 280A at 660V.
    Q What installation methods are supported by the A9-300 series contactor?
    The A9-300 series supports screw installation as well as DIN rail mounting (TH35 or TH75), allowing quick and easy assembly and disassembly to suit various panel configurations.
    Q What are the ambient temperature requirements for installing the A9-300 series contactor?
    The ambient air temperature must not exceed +40°C, and must not exceed +35°C on average within any 24-hour period. The minimum ambient temperature is -5°C. The installation site elevation must not exceed 2000 m.
    Q What application categories are supported by the main circuit of the A9-300 series contactor?
    The main circuit supports AC-1 (non-inductive or micro-inductive loads), AC-2 (wound-rotor motor starting/breaking), AC-3 (cage motor starting and breaking during operation), and AC-4 (cage motor starting, plug braking, reversing, and inching).
    Q What is the arc extinguishing method used in different A9-300 series models?
    Models A9–16 use natural arc extinguishing. Models A9–26 through A9–110 incorporate U-shaped arc extinguishing plates within the body to form a sealed arc chamber, providing excellent arc extinguishing performance with zero arc-over distance.
    Q Can the A9-300 series contactor be mounted at any angle?
    The contactor can be mounted both vertically and horizontally. When mounted vertically, the gradient between the mounting surface and the vertical plane must not exceed ±30° to ensure reliable operation.